Cell counting chamber vs. Sysmex XN-1000 for determining white blood cell count and differentiation for body fluids

Author:

Evren Ebru1ORCID,Us Ebru1ORCID,Hekimoğlu Can Hüseyin2ORCID,Ceren Karahan Zeynep1ORCID

Affiliation:

1. Department of Medical Microbiology and İbn-i Sina Education and Research Hospital Central Microbiology Laboratory, Faculty of Medicine , Ankara University , Ankara , Türkiye

2. Turkish Republic Ministry of Health General Directorate of Public Health, Infectious Diseases and Early Warning Department , Division of Health Care Associated Infections Prevention and Control , Ankara , Türkiye

Abstract

Abstract Objectives Sterile body fluids (BFs) include key information for the diagnosis and monitoring of a variety of diseases. A cornerstone test is the total white blood cell (WBC) count, which comprises the differential of WBC of body fluid analysis. It is important to test automated hematology analyzers that should be verified using patient samples. The aim of this study is to compare both the performance of the Sysmex XN-1000 system’s body fluid module for cell counting and differentiation to the results of a cell counting chamber. Methods This study was performed on 200 routinely laboratory sent BFs. Cell counts and differentiation were determined with both bright-lined Neubauer Cell Counting Chamber and Sysmex XN-1000 system body fluid mode. Results The correlation coefficients of WBC count by two methods indicated very strong correlation (r≥0.90, p<0.0001) for any specimen except pleural fluid. According to Passing-Bablok regression analysis, Sysmex XN-1000 showed acceptable performance according to bias of the slope criteria (<±20%). Conclusions The XN-1000 hematological analyzer’s body fluid mode can rapidly count and identify cells, and it can be used as a simple and rapid screening method for laboratory testing of sterile body fluids, particularly in laboratories with a massive quantity of biological fluids.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,Molecular Biology,Biochemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3