A Black Swan in clinical laboratory practice: the analytical error due to interferences in immunoassay methods

Author:

Clerico Aldo1,Belloni Lucia2,Carrozza Cinzia3,Correale Mario4,Dittadi Ruggero5,Dotti Claudio2,Fortunato Antonio6,Vignati Giulio7,Zucchelli Gian Carlo8,Migliardi Marco9

Affiliation:

1. Laboratory of Cardiovascular Endocrinology and Cell Biology , Department of Laboratory Medicine , Fondazione CNR Toscana G. Monasterio, Scuola Superiore Sant’Anna , Via Trieste 41 , 56126 Pisa , Italy

2. Dipartimento di Medicina di laboratorio , Arcispedale Santa Maria Nuova – IRCCS , Reggio Emilia , Italy

3. Laboratorio Analisi 1 , Fondazione Policlinico Universitario “A. Gemelli” , Roma , Italy

4. Clinical Pathology Unit, IRCCS De Bellis, Castellana Grotte , Bari , Italy

5. Medicina di Laboratorio , Ospedale dell’Angelo ULSS 3 Serenissima , Mestre , Italy

6. U.O.C. Patologia Clinica , ASUR Marche Area Vasta 5 , Ascoli Piceno , Italy

7. ELAS Italia , Magenta , Italy

8. Institute of Clinical Physiology, QualiMedlab , Pisa , Italy

9. S.C. Laboratorio Analisi , A.O. Ordine Mauriziano di Torino , Torino , Italy

Abstract

Abstract It is well known that the results of immunoassay methods can be affected by specific or non-specific interferences, ranging from 0.4% to 4.0%. The presence of interference may greatly compromise the accuracy of immunoassay analyses causing an error in the measurement, producing false-positive or false-negative results. From a clinical point of view, these analytical errors may have serious implications for patient care because they can cause misdiagnosis or inappropriate treatment. Unfortunately, it is a very difficult task to identify the irregular analytical errors related to immunoassay methods because they are not detectable by normal laboratory quality control procedures, are reproducible within the test system, may be clinically plausible and are relatively rare. The first line of defense against erroneous results is to use in laboratory practice only immunoassay systems with the highest level of robustness against interference. The second line of defense is always taking into account the possibility of interference in immunoassay results. A correct approach should be addressed on identification of samples at high risk of interference. The attainment of this goal requires a critical review of the test result in relation to patient’s clinical conditions and literature data, taking into account the analytical characteristics of the immunoassay system. The experts in immunoassay systems should make every effort to find some specific and reliable quality indicators for irregular analytical errors in order to better detect and monitor erroneous immunoassay results due to specific or non-specific interferences.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Micro solutions for macro problems: Challenging thyroid and parathyroid function tests;Endocrinología, Diabetes y Nutrición;2024-08

2. Interferences in immunoassay: An estimate based on ‘real-world’ experience;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;2024-03-18

3. Quality in laboratory medicine and the Journal: walking together;Clinical Chemistry and Laboratory Medicine (CCLM);2022-08-16

4. Value of Thyroid Peroxidase Antibodies in Neuroimmune Diseases: Analysis of Interference During Treatment with Intravenous Immunoglobulins;Laboratory Medicine;2022-03-21

5. Interferences in immunoassays: review and practical algorithm;Clinical Chemistry and Laboratory Medicine (CCLM);2022-03-18

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3