Author:
Bukve Tone,Røraas Thomas,Riksheim Berit Oddny,Christensen Nina Gade,Sandberg Sverre
Abstract
AbstractThe Norwegian Quality Improvement of Primary Care Laboratories (Noklus) offers external quality assurance (EQA) schemes (EQASs) for urine albumin (UA) annually. This study analyzed the EQA results to determine how the analytical quality of UA analysis in general practice (GP) offices developed between 1998 (n=473) and 2012 (n=1160).Two EQA urine samples were distributed yearly to the participants by mail. The participants measured the UA of each sample and returned the results together with information about their instrument, the profession and number of employees at the office, frequency of internal quality control (IQC), and number of analyses per month. In the feedback report, they received an assessment of their analytical performance.The number of years that the GP office had participated in Noklus was inversely related to the percentage of “poor” results for quantitative but not semiquantitative instruments. The analytical quality improved for participants using quantitative instruments who received an initial assessment of “poor” and who subsequently changed their instrument. Participants using reagents that had expired or were within 3 months of the expiration date performed worse than those using reagents that were expiring in more than 3 months.Continuous participation in the Noklus program improved the performance of quantitative UA analyses at GP offices. This is probably in part attributable to the complete Noklus quality system, whereby in addition to participating in EQAS, participants are visited by laboratory consultants who examine their procedures and provide practical advice and education regarding the use of different instruments.
Subject
Biochemistry (medical),Clinical Biochemistry,General Medicine
Reference68 articles.
1. National Kidney Foundation clinical practice guidelines and clinical practice recommendations for diabetes and chronic kidney disease;KDOQI;Am J Kidney Dis,2007
2. MD An innovative Australian point - of - care model for urine albumin : creatinine ratio testing that supports diabetes management in indigenous medical services and has international application;Shephard;Ann Clin Biochem,2005
3. CM and treatment of diabetic nephropathy by primary care physicians;Kraft;Screening J Gen Intern Med,1999
4. reference system for urinary albumin current status;Lieske;Clin Chem Lab Med,2013
5. Is the acceptable as a screening instrument for the early detection of renal disease;Shephard;Ann Clin Biochem,2000
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献