Availability and analytical quality of hemoglobin A1c point-of-care testing in general practitioners’ offices are associated with better glycemic control in type 2 diabetes

Author:

Tollånes Mette C.1,Jenum Anne K.2,Berg Tore Julsrud34,Løvaas Karianne F.1,Cooper John G.15,Sandberg Sverre167

Affiliation:

1. Norwegian Organization for Quality Improvement of Laboratory Examinations (Noklus) , Haraldsplass Deaconess Hospital , Bergen , Norway

2. General Practice Research Unit (AFE), Department of General Practice, Institute of Health and Society , University of Oslo , Oslo , Norway

3. Institute of Clinical Medicine, Faculty of Medicine , University of Oslo , Oslo , Norway

4. Department of Endocrinology, Morbid Obesity and Preventive Medicine , Oslo University Hospital , Oslo , Norway

5. Department of Medicine , Stavanger University Hospital , Stavanger , Norway

6. Department of Global Public Health and Primary Care , University of Bergen , Bergen , Norway

7. Department of Medical Biochemistry and Pharmacology , Haukeland University Hospital , Bergen , Norway

Abstract

Abstract Background It is not clear if point-of-care (POC) testing for hemoglobin A1c (HbA1c) is associated with glycemic control in type 2 diabetes. Methods In this cross-sectional study, we linked general practitioner (GP) data on 22,778 Norwegian type 2 diabetes patients to data from the Norwegian Organization for Quality Improvement of Laboratory Examinations. We used general and generalized linear mixed models to investigate if GP offices’ availability (yes/no) and analytical quality of HbA1c POC testing (average yearly “trueness score”, 0–4), as well as frequency of participation in HbA1c external quality assurance (EQA) surveys, were associated with patients’ HbA1c levels during 2014–2017. Results Twenty-eight out of 393 GP offices (7%) did not perform HbA1c POC testing. After adjusting for confounders, their patients had on average 0.15% higher HbA1c levels (95% confidence interval (0.04–0.27) (1.7 mmol/mol [0.5–2.9]). GP offices participating in one or two yearly HbA1c EQA surveys, rather than the maximum of four, had patients with on average 0.17% higher HbA1c levels (0.06, 0.28) (1.8 mmol/mol [0.6, 3.1]). For each unit increase in the GP offices’ HbA1c POC analytical trueness score, the patients’ HbA1c levels were lower by 0.04% HbA1c (−0.09, −0.001) (−0.5 mmol/mol [−1.0, −0.01]). Conclusions Novel use of validated patient data in combination with laboratory EQA data showed that patients consulting GPs in offices that perform HbA1c POC testing, participate in HbA1c EQA surveys, and maintain good analytical quality have lower HbA1c levels. Accurate HbA1c POC results, available during consultations, may improve diabetes care.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3