Abstract

Abstract Background Detection of intrathecal immunoglobulin G (IgG) synthesis by gold standard oligoclonal bands (OCB) or IgG index remains an integral part of multiple sclerosis (MS) diagnostics, although both methods have weaknesses. Emerging evidence suggests that automated detection of free light chains (FLC) in the cerebrospinal fluid (CSF) has diagnostic performance equal to OCB. The objective of this study was to compare the diagnostic performance of CSF FLC with OCB and IgG index in a large cohort of Scandinavian patients referred for MS evaluation. Methods We prospectively included 230 patients suspected for MS. They are composed of patients with MS (n=96), clinically isolated syndrome (n=37), other neurological diseases (OND, n=31) and symptomatic controls (SC, n=66). CSF and serum samples were analyzed for kappa and lambda FLC, OCB and IgG index. Diagnostic performance was evaluated by receiver operating characteristic (ROC) analysis. Results Both the absolute concentration of CSF-kappa and the kappa index had excellent MS diagnostic performances with ROC area under the curve of 0.93 and 0.94 (MS vs. SC+OND). At the 0.42 mg/L cutoff, CSF-kappa had sensitivity and specificity of 93.8% and 85.6%, whereas sensitivity and specificity for OCB was 82.3% and 93.8% (72.9% and 95.9% for IgG index at cutoff 0.64). CSF-lambda and lambda index performed inferior to CSF-kappa and kappa index. Conclusions CSF-kappa and kappa index represent automated, rapid and low-cost alternatives to OCB. Using merely the absolute concentration of CSF-kappa is a logistic advantage in the clinical laboratories.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3