Inter-assay diagnostic accuracy of cerebrospinal fluid kappa free light chains for the diagnosis of multiple sclerosis

Author:

Dekeyser Cathérine,De Kesel Pieter,Cambron Melissa,Vanopdenbosch Ludo,Van Hijfte Liesbeth,Vercammen Martine,Laureys Guy

Abstract

BackgroundCerebrospinal fluid (CSF) kappa free light chain (κFLC) measures gained increasing interest as diagnostic markers in multiple sclerosis (MS). However, the lack of studies comparing assay-dependent diagnostic cutoff values hinders their use in clinical practice. Additionally, the optimal κFLC parameter for identifying MS remains a subject of ongoing debate.ObjectivesThe aim of this study was to compare same-sample diagnostic accuracies of the κFLC index, κIgG index, CSF κFLC/IgG ratio, and isolated CSF κFLC (iCSF-κFLC) between two reference centers using different methods.MethodsPaired serum and CSF samples were analyzed for κFLC and albumin concentrations by Freelite®-Optilite (Sint-Jan Bruges hospital) and N Latex®-BNII (Ghent University hospital). Diagnostic performance to differentiate MS from controls was assessed using ROC curve analysis.ResultsA total of 263 participants were included (MS, n = 80). Optimal diagnostic cutoff values for the κFLC index (Freelite®-Optilite: 7.7; N Latex®-BNII: 4.71), κIgG index (Freelite®-Optilite: 14.15, N Latex®-BNII: 12.19), and CSF κFLC/IgG ratio (Freelite®-Optilite: 2.27; N Latex®-BNII: 1.44) differed between the two methods. Sensitivities related to optimal cutoff values were 89.9% (Freelite®-Optilite) versus 94.6% (N Latex®-BNII) for the κFLC index, 91% (Freelite®-Optilite) versus 92.2% (N Latex®-BNII) for the κIgG index, and 81.3% (Freelite®-Optilite) versus 91.4% (N Latex®-BNII) for the CSF κFLC/IgG ratio. However, for iCSF-κFLC, optimal diagnostic cutoff values (0.36 mg/L) and related specificities (81.8%) were identical with a related diagnostic sensitivity of 89.9% for Freelite®-Optilite and 90.5% for N Latex®-BNII. The diagnostic performance of the κFLC index [area under the curve (AUC) Freelite®-Optilite: 0.924; N Latex®-BNII: 0.962] and κIgG index (AUC Freelite®-Optilite: 0.929; N Latex®-BNII: 0.961) was superior compared to CSF oligoclonal bands (AUC: 0.898, sensitivity: 83.8%, specificity: 95.9%).ConclusionsThe κFLC index and the κIgG index seem to be excellent markers for identifying MS, irrespective of the method used for κFLC quantification. Based on the AUC, they appear to be the measures of choice. For all measures, optimal cutoff values differed between methods except for iCSF-κFLC. iCSF-κFLC might therefore serve as a method-independent, more cost-efficient, initial screening measure for MS. These findings are particularly relevant for clinical practice given the potential future implementation of intrathecal κFLC synthesis in MS diagnostic criteria and for future multicentre studies pooling data on κFLC measures.

Publisher

Frontiers Media SA

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3