Comparative evaluation of the Aptima HIV-1 Quant Dx assay and COBAS TaqMan HIV-1 v2.0 assay using the Roche High Pure System for the quantification of HIV-1 RNA in plasma

Author:

Schalasta Gunnar,Börner Anna,Speicher Andrea,Enders Martin

Abstract

AbstractQuantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma has become the standard of care in the management of HIV-infected patients. There are several commercially available assays that have been implemented for the detection of HIV-1 RNA in plasma. Here, the new Hologic AptimaThe performance characteristics of the assays were assessed using commercially available HIV reference panels, dilution of the WHO 3rd International HIV-1 RNA International Standard (WHO-IS) and plasma from clinical specimens. Assay performance was determined by linear regression, Deming correlation analysis and Bland-Altman analysis.Testing of HIV-1 reference panels revealed excellent agreement. The 61 clinical specimens quantified in both assays were linearly associated and strongly correlated.The Aptima HIV assay offers performance comparable to that of the HPS/CTM assay and, as it is run on a fully automated platform, a significantly improved workflow.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Reference36 articles.

1. Plasma viral load and CD lymphocytes as prognostic markers of HIV infection;Mellors;Ann Intern Med,1997

2. Multicenter performance evaluation of a new TaqMan PCR assay for monitoring human immunodeficiency virus RNA load;Perrin;J Clin Microbiol,2006

3. AD AD LP Lack of correlation between three commercial platforms for the evaluation of human immunodeficiency virus type HIV viral load at the clinically critical lower limit of quantification;Yan;J Clin Virol,2010

4. on behalf of the BHIVA Guidelines Subcommittee British HIV Association guidelines for the routine investigation and monitoring of adult HIV infected individuals HIV;Asboe;Med,2011

5. Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type hepatitis virus;Schutten;RNA J Clin Microbiol,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3