Quantitative urine test strip reading for leukocyte esterase and hemoglobin peroxidase

Author:

Oyaert Matthijs N.,Himpe Jonas,Speeckaert Marijn M.,Stove Veronique V.,Delanghe Joris R.

Abstract

Abstract Background: Recently, urine test strip readers have become available for automated test strip analysis. We explored the possibilities of the Sysmex UC-3500 automated urine chemistry analyzer based on complementary metal oxide semiconductor (CMOS) sensor technology with regard to accuracy of leukocyte esterase and hemoglobin peroxidase results. We studied the influence of possible confounders on these measurements. Methods: Reflectance data of leukocyte esterase and hemoglobin peroxidase were measured using CMOS technology on the Sysmex UC-3500 automated urine chemistry analyzer. Analytical performance (imprecision, LOQ) as well as the correlation with white blood cell (WBC) and red blood cell (RBC) counts (Sysmex UF-5000) were studied. Furthermore, the influence of urinary dilution, haptoglobin, pH and ascorbic acid as confounders was determined. Results: Within- and between-run imprecision (reflectance signal) ranged from 1.1% to 3.6% and 0.9% to 4.2% for peroxidase and 0.4% to 2.5% and 0.4% to 3.3% for leukocyte esterase. Good agreement was obtained between the UF-5000 for RBCs and peroxidase reflectance (r=0.843) and for WBCs and leukocyte esterase (r=0.821). Specific esterase activity decreased for WBC counts exceeding 100 cells/μL. Haptoglobin influenced the peroxidase activity, whereas leukocyte esterase and peroxidase activities showed a pH optimum between 5.0 and 6.5. A sigmoidal correlation was observed between urinary osmolality and peroxidase activity. Conclusions: CMOS technology allows to obtain high quality test strip results for assessing WBC and RBC in urine. Quantitative peroxidase and leukocyte esterase are complementary with flow cytometry and have an added value in urinalysis, which may form a basis for expert system development.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference46 articles.

1. Quantitative evaluation of urinalysis tests strips;Clin Chem,2002

2. Urine analysis performed by flow cytometry: reference range determination and comparison to morphological findings, dipstick chemistry and bacterial culture results: a multicenter study;Clin Nephrol,2001

3. Performance evaluation of the new fully automated urine particle analyser UF-50000 compared to the reference method of the Fuchs-Rosenthal chamber;Clin Chim Acta,2017

4. Fast determination of haptoglobin phenotype and calculation of hemoglobin binding capacity using high pressure gel permeation chromatography;Clin Chim Acta,2000