Estimated urinary osmolality based on combined urinalysis parameters: a critical evaluation

Author:

Oyaert Matthijs,Speeckaert Marijn M.,Delanghe Joris R.

Abstract

Abstract Background Urinary conductivity allows a coarse prediction of urinary osmolality in most cases but is insensitive to the osmolal contribution of uncharged particles and the presence of roentgen contrast media. Urinary osmolality can be estimated on the recently introduced Sysmex UF-5000 urine analyzer using conductivity. In this study, we evaluated the analytical performance of this research parameter. Secondly, we aimed to improve the manufacturer’s algorithm for estimating urinary osmolality, based on standard urinalysis parameters (creatinine, glucose, relative density). Methods The analytical performance was determined and a prediction model to estimate urinary osmolality based on urinalysis parameters was developed. We further developed and validated a prediction model using another set of routine urine samples. In addition, the influence of roentgen contrast media on urinary osmolality was studied. Results The within-run and between imprecision for osmolality and conductivity measured on the Sysmex UF-5000 ranged from 1.1% to 4.9% and 0.7% to 4.8%, respectively. Multiple regression analysis revealed urinary creatinine, conductivity and relative density to be the strongest predictors to estimate urinary osmolality. A mean difference of 1.3 mOsm/kg between measured and predicted osmolality demonstrated that the predictive performance of our model was favorable. An excellent correlation between the relative density and % contrast media was demonstrated. Conclusions Urinary osmolality is an important parameter for assessing specimen dilution in urinalysis. Urinary conductivity, along with relative density and urinary creatinine allows a coarse prediction of urinary osmolality and is insensitive to the osmolal contribution of uncharged particles and the presence of roentgen contrast media.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Reference48 articles.

1. Reference values for analytes of 24-h urine collections known to be complete;Ann Clin Biochem,1988

2. Use of SGLT2 inhibitors in type 2 diabetes: weighing the risks and benefits;Diabetologia,2018

3. Limit of blank, limit of detection and limit of quantification;Clin Biochem Rev,2008

4. Comparison of hydrometry, refractometry, osmometry, and Ames N-Multistix SG in estimation of urinary concentration;Aust Paediatr J,1985

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3