Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes

Author:

Juricic Gordana,Bakliza Ana,Saracevic Andrea,Kopcinovic Lara Milevoj,Dobrijevic Sanja,Drmic Sandra,Simundic Ana-Maria

Abstract

AbstractDelayed sample processing can affect accurate glucose measurement. Our aim was to investigate the stability of glucose in samples collected in serum, sodium fluoride/potassium oxalate (NaF/KOx) and Glucomedics tubes processed according to different controlled pre-centrifugation delays (up to 180 min after venipuncture) in order to simulate prolonged sample transport between venipuncture and centrifugation.Samples were collected from healthy volunteers (n=80) into either serum or NaF/KOx and Glucomedics tubes. Glucose concentration was measured in samples centrifuged immediately after venipuncture and compared with tubes processed with a delay of 60, 120 and 180 min prior to centrifugation. Differences between baseline and respective delayed centrifugation glucose value for each tube type were tested using the paired t-test. Mean bias calculated for each tube type and delay protocol was compared to recommended quality specifications for glucose (2.2%).Glucose concentrations measured in all three delayed tube types were lower in comparison to respective baseline glucose concentrations measured in immediately processed tube (p<0.001). The highest decrease in glucose was observed in serum tubes in all specified time points (p<0.001), while glucose was most stable in Glucomedics tubes (p<0.001). The decrease in glucose observed for serum and NaF/KOx tubes was clinically significant at all specified time points while the bias for Glucomedics tubes did not exceed the criteria even with a centrifugation delay of 180 min.Glucose stability in un-centrifuged Glucomedics tubes is much superior to serum and NaF/KOx tubes. Glucomedics tubes can be left un-centrifuged for up to 3 h without affecting glucose concentration.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference44 articles.

1. Glycolysis inhibitors negatively bias blood glucose measurements : potential impact on the reported prevalence of diabetes mellitus;Waring;J Clin Pathol,2007

2. Package insert for Glucose on the Systems and the system Laboratories REF;Aeroset;Architect,2010

3. Evacuated blood collection system for in vitro diagnostic use Bio One Kremsmünster;Greiner;Austria Rev,2013

4. The modernisation of pathology and laboratory medicine in the UK : networking into the future;Beastall;Clin Biochem Rev,2008

5. Evacuated blood collection system for in vitro diagnostic use Bio One Kremsmünster;Greiner;Austria Rev,2013

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3