Maintaining glucose integrity ex-vivo: Impact of preanalytical specimen handling

Author:

Islam Md Nahidul12ORCID,Lyons Claire1ORCID,Griffin Tomas P34,Hamon Siobhan1,Dunne Fidelma P5,O’Shea Paula M6

Affiliation:

1. Department of Clinical Biochemistry, Saolta University Health Care Group (SUHCG), Galway University Hospitals, Galway, Ireland

2. School of Biological and Chemical Sciences, University of Galway, Galway, Ireland

3. School of Medicine, University of Limerick, Limerick, Ireland

4. Department of Diabetes, University Hospital Limerick, Limerick, Ireland

5. School of Medicine, College of Medicine, Nursing and Health Sciences, University of Galway, Ireland

6. Department of Clinical Chemistry & Diagnostic Endocrinology, Mater Misericordiae University Hospital, Dublin, Ireland

Abstract

Background Adopting the WHO protocol for glucose analysis is arguably impractical in the routine clinical setting. Deviations may develop due to a lack of understanding regarding the impact of glycolysis on the accuracy of results. Aim We sought to assess the stability of glucose in two different blood collection tubes (BCT), BD Vacutainer® FX ‘Fl-Ox’ and Greiner Vacuette® FC-Mix ‘FC-Mix’ stored at room temperature (RT:18–22°C) and 4°C over 8.5 days. Method Each participant provided venous whole blood collected into 51 BCTs; ‘Fl-Ox’ (n = 26) and ‘FC-Mix’ (n = 25). One Fl-Ox sample from each participant was handled according to the WHO recommended method. The remaining BCTs were stored at 4°C/RT prior to analyses at designated study timepoints. Glucose was measured using the hexokinase assay on the Cobas® 8000 platform. Results Participants (n = 8, Male = 2) were aged 24–56 years. Plasma glucose measured in FI-Ox BCTs according to the WHO sample-handling method had a median concentration of 5.73 mmol/L (Range: 5.39–10.37 mmol/L). Glucose decreased by greater than minimal difference (>0.26 mmol/L) in blood collected into Fl-Ox and stored @4°C/RT within 24 h of phlebotomy. FC-Mix BCT maintained glucose <0.26 mmol/L @4°C over a period of 8.5 days and up to 4 days @RT when compared to the WHO recommended method. Conclusion Glucose in FC-Mix BCT stored @4°C demonstrated the best agreement with results determined using the WHO specifications. When FC-Mix tubes were stored @RT, glucose was stable for 4 days. These findings suggest that the FC-Mix BCT effectively inhibits glycolysis and should be introduced into routine clinical practice.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3