Near-field resonant photon sorting applied: dual-band metasurface quantum well infrared photodetectors for gas sensing
Author:
Hainey Mel F.1ORCID, Mano Takaaki1, Kasaya Takeshi1, Ochiai Tetsuyuki1, Osato Hirotaka1, Watanabe Kazuhiro1, Sugimoto Yoshimasa1, Kawazu Takuya1, Arai Yukinaga1, Shigetou Akitsu1, Miyazaki Hideki T.1
Affiliation:
1. National Institute for Materials Science , Tsukuba , Ibaraki 305-0047 , Japan
Abstract
Abstract
Two photodetectors for measuring transmission and two bulky, separated narrowband filters for picking a target gas absorption line and a non-absorbing reference from broadband emission are typically required for dual-band non-dispersive infrared (NDIR) gas sensing. Metal-dielectric-metal (MDM) metasurface plasmon cavities, precisely controllable narrowband absorbers, suggest a next-generation, nanophotonic approach. Here, we demonstrate a dual-band MDM cavity detector that consolidates the function of two detectors and two filters into a single device by employing resonant photon sorting-a function unique to metasurfaces. Two MDM cavities sandwiching a quantum well infrared photodetector (QWIP) with distinct resonance wavelengths are alternately arranged in a subwavelength period. The large absorption cross section of the cavities ensures ~95% efficient lateral sorting of photons by wavelength into the corresponding detector within a near-field region. The flow of incident photons is thus converted into two independent photocurrents for dual-band detection. Our dual-band photodetectors show competitive external quantum efficiencies up to 38% (responsivity 2.1 A/W, peak wavelength 6.9 5m) at 78 K. By tailoring one resonance to an absorption peak of NO2 (6.25 5m) and the other to a non-absorbing reference wavelength (7.15 5m), NDIR NO2 gas sensing with 10 ppm accuracy and 1 ms response times is demonstrated. Through experiment and numerical simulation, we confirm near-perfect absorption at the resonant cavity and suppressed absorption at its non-resonant counterpart, characteristic of resonant photon sorting. Dual-band sensing across the mid-infrared should be possible by tailoring the cavities and quantum well to desired wavelengths.
Funder
Iketani Science and Technology Foundation Japan Society for the Promotion of Science National Institute for Materials Science Center for Functional Sensor and Actuator Ministry of Education, Culture, Sports, Science and Technology, Japan
Publisher
Walter de Gruyter GmbH
Subject
Electrical and Electronic Engineering,Atomic and Molecular Physics, and Optics,Electronic, Optical and Magnetic Materials,Biotechnology
Reference38 articles.
1. J. Hodgkinson and R. P. Tatam, "Optical gas sensing: a review," Meas. Sci. Technol., vol. 24, no. 1, p. 012004, Jan. 2013, https://doi.org/10.1088/0957-0233/24/1/012004. 2. D. Popa and F. Udrea, "Towards integrated mid-infrared gas sensors," Sensors, vol. 19, no. 9, p. 2076, 2019, https://doi.org/10.3390/s19092076. 3. M. S. Peckham, A. Finch, and B. Campbell, "Analysis of transient HC, CO, NOx and CO2 emissions from a GDI engine using fast response gas analyzers," SAE Int. J. Engines, vol. 4, no. 1, pp. 1513-1522, Apr. 2011, https://doi.org/10.4271/2011-01-1227. 4. M. Duckhouse, M. Peckham, B. Mason, E. Winward, and M. Hammond, "In-cylinder CO2 sampling using skip-firing method," in Volume 2: Emissions Control Systems; Instrumentation, Controls, and Hybrids; Numerical Simulation; Engine Design and Mechanical Development, 2, November, 2018, https://doi.org/10.1115/ICEF2018-9570. 5. G. Livjque and O. J. F. Martin, "Tunable composite nanoparticle for plasmonics," Opt. Lett., vol. 31, no. 18, pp. 2750-2752, 2006, https://doi.org/10.1364/ol.31.002750.
Cited by
21 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|