High-sensitive and disposable myocardial infarction biomarker immunosensor with optofluidic microtubule lasing

Author:

Niu Panpan123,Jiang Junfeng123ORCID,Liu Kun123,Wang Shuang123,Wang Tong123,Liu Yize123,Zhang Xuezhi123,Ding Zhenyang123,Liu Tiegen123

Affiliation:

1. School of Precision Instrument and Opto-electronics Engineering , Tianjin University , Tianjin 300072 , China

2. Key Laboratory of Opto-electronics Information Technology (Tianjin University), Key Laboratory of Micro Opto-electro Mechanical System Technology (Tianjin University), Ministry of Education , Tianjin 300072 , China

3. Tianjin Optical Fiber Sensing Engineering Center, Institute of Optical Fiber Sensing of Tianjin University , Tianjin 300072 , China

Abstract

Abstract The early diagnosis of myocardial infarction can significantly improve the survival rate in emergency treatment, which is mainly implemented by the immunoassay for myocardial infarction biomarkers such as cardiac troponins in blood. In this work, a disposable optofluidic microtubule whispering gallery mode (WGM) immunosensor for label-free cardiac troponin I-C (cTnI-C) complex detection has been proposed and demonstrated with active interrogation enhancement. The disposable microtubule is simply fabricated by a silica capillary with pressurized tapering technology for thin-wall, and the cTnI antibodies are immobilized on the inner wall surface of the microtubule through the self-adherent polydopamine substrate. By configuring the two coupling microfibers, the double-fiber-coupled microtubule cavity can serve as a tunable filter for the mutual-coupled polarimetric fiber ring laser (FRL), whose output laser wavelength is determined by the cTnI-C concentration in the optofluidic microtubule with inherent microfluidic channel. Due to the cyclic-cumulative gain of the FRL, the characteristic resonant peak of optical sensing signal is enhanced in the spectral width compression and the optical signal-to-noise ratio improvement, and therefore the optical immunosensor for cTnI-C can be achieved by tracking the output laser wavelength of the FRL conveniently. The dynamic binding and unbinding process of cTnI-C antigen–antibody is illustrated by monitoring the lasing peak wavelength continuously. Our all-fiber immunosensor demonstrated here has the advantages of fast label-free detection, real-time monitor, high sensitivity and disposable sensing element, which can be an innovative detecting tool in early diagnosis of myocardial infarction.

Publisher

Walter de Gruyter GmbH

Subject

Electrical and Electronic Engineering,Atomic and Molecular Physics, and Optics,Electronic, Optical and Magnetic Materials,Biotechnology

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3