Volume reduction of water samples to increase sensitivity for radioassay of lead contamination
-
Published:2022-05-06
Issue:7
Volume:12
Page:
-
ISSN:2190-5487
-
Container-title:Applied Water Science
-
language:en
-
Short-container-title:Appl Water Sci
Author:
Aguilar-Arevalo A.ORCID, Canet C.ORCID, Cruz-Pérez M. A., Deisting A.ORCID, Dias A.ORCID, D’Olivo J. C., Favela-Pérez F., Garcés E. A.ORCID, González Muñoz A., Guerra-Pulido J. O.ORCID, Mancera-Alejandrez J., Marín-Lámbarri D. J.ORCID, Martinez Montero M., Monroe J. R.ORCID, Paling S., Peeters S. J. M.ORCID, Scovell P. R., Türkoğlu C.ORCID, Vázquez-Jáuregui E.ORCID, Walding J.ORCID
Abstract
AbstractThe World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity range of low-cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 ($${}^{210}$$
210
Pb), as a means to increase the solute’s concentration. $${}^{210}$$
210
Pb is a radioactive lead isotope and its concentration in a water sample can be measured with e.g. High Purity Germanium (HPGe) detectors at the Boulby Underground Germanium Suite. Concentrations close to the WHO limit have not been examined. This paper presents a measurement of the volume reduction technique retaining $$99\pm (9)$$
99
±
(
9
)
% of $${}^{210}$$
210
Pb starting from a concentration of $$1.9 \times 10^{-6}$$
1.9
×
10
-
6
ppb before reduction and resulting in $$2.63 \times 10^{-4}$$
2.63
×
10
-
4
ppb after reduction. This work also applies the volume reduction technique to London tap water and reports the radioassay results from gamma counting in HPGe detectors. Among other radio-isotopes, $${}^{40}$$
40
K, $${}^{210}$$
210
Pb, $${}^{131}$$
131
I and $${}^{177}$$
177
Lu were identified at measured concentrations of $$2.83 \times 10^{3}$$
2.83
×
10
3
ppb, $$2.55 \times 10^{-7}$$
2.55
×
10
-
7
ppb, $$5.06 \times 10^{-10}$$
5.06
×
10
-
10
ppb and $$5.84 \times 10^{-10}$$
5.84
×
10
-
10
ppb in the London tap water sample. This technique retained $${90 \pm 50}{\%}$$
90
±
50
%
of $${}^{40}$$
40
K. Stable lead was inferred from the same water sample at a measured concentration of 0.012 ppb, prior to reduction.
Funder
science and technology facilities council dgapa unam conacyt
Publisher
Springer Science and Business Media LLC
Subject
Water Science and Technology
Reference23 articles.
1. Affinity Water Limited Limited (2021) Water supply zone: Bagshot/Sunninghill (AF064). https://www.affinitywater.co.uk/docs/water-quality/AF064.pdf. Accessed 24 May 2021 2. Aguilar-Arevalo A, Alvarado-Mijangos S, Bertou X, Canet C, Cruz-Pérez M, Deisting A, Dias A, Dolivo J, Favela-Pérez F, Garcés E, Muñoz AG, Guerra-Pulido J, Mancera-Alejandrez J, Marín-Lámbarri D, Montero MM, Monroe J, Ortega-Hernández CI, Paling S, Peeters S, Rodríguez DRE, Scovell P, Türkoğlu C, Vázquez-Jáuregui E, Walding J (2020a) Characterization of germanium detectors for the first underground laboratory in Mexico. J Instrum 15(11):P11014–P11014. https://doi.org/10.1088/1748-0221/15/11/p11014 3. Aguilar-Arevalo A et al (2020b) Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring. Sensors 20(20):5746. https://doi.org/10.3390/s20205746 4. Boger J et al (2000) The Sudbury neutrino observatory. Nucl Instrum Methods A 449:172–207. https://doi.org/10.1016/S0168-9002(99)01469-2 5. Cao C, Li N, Yang X, Zhao J, Li Y, Cai Z, Wen L, Luo X, Heng, Y, Ding Y (2020) A practical approach of high precision U and TH concentration measurement in acrylic
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|