Digital templating for the implantation of a curved short hip stem with an anterolateral MIS approach shows gender differences in digital templating

Author:

Luger MatthiasORCID,Hochgatterer Rainer,Klotz Matthias C.,Hipmair Günter,Gotterbarm Tobias,Schauer Bernhard

Abstract

Abstract Purpose Digital templating shows reliable accuracy for straight stem systems. In recent years, the implantation of short stems through minimally invasive approaches has gained more popularity. Minimally invasive approaches (MIS) show the risk of undersizing femoral components. Therefore, we questioned the planning adherence for a curved short stem and a bi-hemispherical acetabular cup implanted through an anterolateral MIS approach. Methods A consecutive series of 964 hips (index surgery between 2014 and 2019) with Fitmore® curved short stem and Allofit/-S® acetabular cup (both ZimmerBiomet Inc, Warsaw, IN) were included. Preoperative digital templating was conducted anterior–posterior (AP) digital radiographs of the hip using mediCAD® version 5.1 (Hectec GmbH, Altdorf, Germany). The templates of acetabular and femoral components (offset option and stem size) were retrospectively evaluated for general adherence, and according to sex, BMI and planner’s experience. Results Planning adherence for the exact offset option was 70.6 and 21.6% for exact offset option and stem size. Adherence for acetabular cup  ± 1 size was 74.8%. A significant difference between male and female patients for the offset option could be found (p = 0.03, z = −2983). In 22.5% of male patients, an offset option one size higher and in 12.3% of female patients an offset option one size smaller than templated was used intraoperatively Conclusion Digital templating for the Fitmore® stem in cementless THA with a minimally invasive anterolateral approach shows comparable planning adherence to the existing literature for this cementless short stem. However, a lower planning adherence was detected compared to conventional straight stem systems. In male patients, the femoral offset is frequently undersized and in female patients frequently oversized compared to the preoperative plan. Surgeons should be aware of this difficulty in digital templating for Fitmore® hip stem.

Funder

Johannes Kepler University Linz

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3