Prosthetic orientation, limb alignment, and soft tissue balance with bi-cruciate stabilized total knee arthroplasty: a comparison between the handheld robot and conventional techniques

Author:

Matsumoto TomoyukiORCID,Nakano Naoki,Hayashi Shinya,Takayama Koji,Maeda Toshihisa,Ishida Kazunari,Kuroda Yuichi,Matsushita Takehiko,Niikura Takahiro,Muratsu Hirotsugu,Kuroda Ryosuke

Abstract

Abstract Purpose This study aimed to examine the prosthetic orientations, limb alignment, intraoperative soft tissue balance, and early clinical outcomes associated with the use of the relatively new handheld robot technique compared to those associated with the use of the conventional alignment guide for bi-cruciate stabilized total knee arthroplasty (TKA). Methods This retrospective cohort study compared the prosthetic orientation and limb alignment of 35 patients who underwent TKA using robotic assistance (robot group) with those of patients who underwent TKA using a conventional alignment guide (control group). The coronal femoral component alignment (FCA), coronal tibial component alignment (TCA), and the hip-knee-ankle (HKA) angle were compared between groups. Intraoperative soft tissue balance, including the joint component gap and varus/valgus balance assessed by an offset-type tensor, were also compared between groups. One year postoperatively, the clinical outcomes, including the range of motion and 2011 Knee Society Score (KSS), were compared between groups. Results The HKA angle and FCA were 0.1° varus and 0.1° varus, respectively, in the robot group and 1.3° varus and 1.3° varus, respectively, in the control group. The difference in the HKA angle and the FCA, but not the TCA, between groups was statistically significant (p < 0.05). The intraoperative soft tissue balance showed more stable joint component gaps and varus/valgus balances throughout the range of motion in the robot group than in the control group. Clinical outcomes of the robot group showed superior 2011 KSS subscales compared to those of the control group. Conclusion The accuracy of the implantations and stable soft tissue balance in the robot group were superior to those of the control group. The robot group also had superior patient-reported scores for early clinical outcomes.

Funder

Kobe University

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3