Preoperative evaluation of femoral and tibial sagittal alignment in robotic-assisted and conventional total knee arthroplasty and consequences for practice

Author:

Peng Yue,Ding Ran,Li Ming,Wang Guangxue,Zhong Zikang,Wei Lingbo,Huang Cheng,Zhang Nianfei,Hernigou Philippe,Wang WeiguoORCID

Abstract

Abstract Purpose Robot-assisted total knee arthroplasty (TKA) was developed to improve the precision and accuracy of implant placement in conventional TKA. However, the angular differences between referenced axes in robot-assisted TKA and conventional TKA remain unclear. The aim of this study was to investigate the angular differences in sagittal alignment between robot-assisted TKA and conventional TKA for both the femur and the tibia and to discuss their clinical implications. Methods We conducted a retrospective analysis of data from 100 patients (97 patients) who underwent computed tomography (CT) for Mako TKA. We measured the angle between the robot femoral axis (RFA) and conventional femoral axis (CFA) in the sagittal plane and the angle between the robot tibial axis (RTA) and the conventional tibial axis (CTA). Angles were compared between the sexes. Correlation analysis was conducted between the angles and height. Results In the sagittal plane, the mean RFA-CFA angle was 2.2° ± 1.6°, and the mean RTA-CTA angle was 2.3° ± 1.6°. There were no significant differences between the two angles among males and females (p > 0.05). There was a correlation between the RFA-CFA angle and RTA-CTA angle (p < 0.001, r = 0.33), and there was a correlation between height and the combination of the RFA-CFA angle and RTA-CTA angle (p = 0.03, r = 0.22). Conclusion There are angular differences between the axes referenced by robot-assisted TKA and those referenced by conventional TKA, which may be influenced by patient height. Correctly understanding these differences is crucial when evaluating the implant position and surgical outcomes after robot-assisted TKA. Furthermore, caution should be taken when assessing the flexion–extension angle of the knee since the angles displayed in the Mako system are different from the angles measured with intramedullary anatomical axes. After all, sagittal alignment principles differ between robot-assisted and conventional TKA; however, further studies are required to determine which principle is more appropriate or to modify these principles.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3