Abstract
Abstract
Purpose
The effect of open release of a post-traumatic elbow contracture on the stability of the joint has not been so far studied in vivo. Resection of elbow joint capsule, the key element of surgery, was reported to have no effect on the stability of cadaveric elbows. The joint capsule is yet known to participate in maintaining elbow stability as one of secondary stabilizers.
Methods
We assessed elbow joint laxity in 39 patients who underwent an open contracture release via the ‘column procedure’ described by B. Morrey and P. Mansat within the preceeding three to nine months. The measurements were taken with an apparatus designed particularly for this experiment according to the predetermined protocol. A preliminary part of the experiment showed that there was no significant difference between laxity of two elbow joints in healthy volunteers. Laxity of the operated elbows could be then compared with the contralateral joints.
Results
Mean absolute difference of laxity between healthy and operated elbows was 1.55° (0.1°–4.1°, SD = 1.1) being significantly lower than 2°, p = 0.0056. The difference of the joint laxity between the operated and healthy elbows did not differ statistically significantly by more than 0.6° from the difference of the laxity of two healthy elbows and, therefore, is not clinically noticeable.
Conclusions
Our experiment confirmed that the ‘column procedure’ is a safe procedure which does not compromise the stability of the elbow joint.
Funder
Military Institute of Medicine
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Reference29 articles.
1. Kai-Nan An BM (1993) Biomechanics of the elbow. In: Morrey BF (ed) The elbow and its disorders. W.B. Saunders Company, Philadephia, pp 53–73
2. Morrey BF, An KN (1983) Articular and ligamentous contributions to the stability of the elbow joint. Am J Sports Med 11(5):315–319. https://doi.org/10.1177/036354658301100506
3. Nielsen KK, Olsen BS (1999) No stabilizing effect of the elbow joint capsule. A kinematic study. Acta Orthop Scand 70(1):6–8
4. Dos Remedios C, Chantelot C, Migaud H, Le Nen D, Fontaine C, Landjerit B (2003) Effect of anterior and posterior capsule release on elbow joint stability: an experimental study. Rev Chir Orthop Reparatrice Appar Mot 89(8):693–698
5. Morrey BF, Askew LJ, Chao EY (1981) A biomechanical study of normal functional elbow motion. J Bone Joint Surg Am 63(6):872–877