The column procedure preserves elbow stability on biomechanical testing

Author:

Podgórski Andrzej P.ORCID,Kordasiewicz Bartłomiej,Pomianowski Stanisław

Abstract

Abstract Purpose The effect of open release of a post-traumatic elbow contracture on the stability of the joint has not been so far studied in vivo. Resection of elbow joint capsule, the key element of surgery, was reported to have no effect on the stability of cadaveric elbows. The joint capsule is yet known to participate in maintaining elbow stability as one of secondary stabilizers. Methods We assessed elbow joint laxity in 39 patients who underwent an open contracture release via the ‘column procedure’ described by B. Morrey and P. Mansat within the preceeding three to nine months. The measurements were taken with an apparatus designed particularly for this experiment according to the predetermined protocol. A preliminary part of the experiment showed that there was no significant difference between laxity of two elbow joints in healthy volunteers. Laxity of the operated elbows could be then compared with the contralateral joints. Results Mean absolute difference of laxity between healthy and operated elbows was 1.55° (0.1°–4.1°, SD = 1.1) being significantly lower than 2°, p = 0.0056. The difference of the joint laxity between the operated and healthy elbows did not differ statistically significantly by more than 0.6° from the difference of the laxity of two healthy elbows and, therefore, is not clinically noticeable. Conclusions Our experiment confirmed that the ‘column procedure’ is a safe procedure which does not compromise the stability of the elbow joint.

Funder

Military Institute of Medicine

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Reference29 articles.

1. Kai-Nan An BM (1993) Biomechanics of the elbow. In: Morrey BF (ed) The elbow and its disorders. W.B. Saunders Company, Philadephia, pp 53–73

2. Morrey BF, An KN (1983) Articular and ligamentous contributions to the stability of the elbow joint. Am J Sports Med 11(5):315–319. https://doi.org/10.1177/036354658301100506

3. Nielsen KK, Olsen BS (1999) No stabilizing effect of the elbow joint capsule. A kinematic study. Acta Orthop Scand 70(1):6–8

4. Dos Remedios C, Chantelot C, Migaud H, Le Nen D, Fontaine C, Landjerit B (2003) Effect of anterior and posterior capsule release on elbow joint stability: an experimental study. Rev Chir Orthop Reparatrice Appar Mot 89(8):693–698

5. Morrey BF, Askew LJ, Chao EY (1981) A biomechanical study of normal functional elbow motion. J Bone Joint Surg Am 63(6):872–877

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3