Exposure of cleaning workers to chemical agents and physical conditions in swimming pools and spas

Author:

Ruokolainen JoonasORCID,Hyttinen Marko,Sorvari Jouni,Pasanen Pertti

Abstract

AbstractSwimming pools and spas require a high hygiene level, and therefore constant cleaning. In this study, cleaning workers’ exposure to volatile organic compounds (VOCs), trichloramine (TCA), and particulate matter (PM) in the swimming pools and spas were evaluated. Also, statistical methods were employed to determine what activities affect the exposure to disinfection byproducts (DBPs). The study was conducted in 32 swimming pools and spas. The measurement locations were pool areas, bathrooms, and locker rooms, both during cleaning and opening hours. During the cleaning, the total volatile organic compound (TVOC) concentrations were low, on average 96, 251, and 91 µg/m3 for locker rooms, bathrooms, and pool areas, respectively. Similarly, during the opening hours, the TVOC concentrations were on average 78, 125, and 83 µg/m3, for locker rooms, bathrooms, and pool areas, respectively. This is in line with previous studies investigating cleaning work in other environments. The most prevalent compounds during the cleaning were 2-(2-butoxyethoxy)ethanol (DEGBE), 2-(2-ethoxyethoxy)ethanol (DEGEE), 2-butyl-1-octanol, trichloromethane (chloroform), decamethylcyclopentasiloxane (D5), and carbon tetrachloride. The most prevalent compounds during the opening hours were D5, D-limonene, carbon tetrachloride (bathrooms and pool areas), and trichloromethane (bathrooms and pool areas). The TCA concentrations during the cleaning in the bathrooms and pool areas were on average 60 and 67 µg/m3, respectively, and during the opening hours, 28 and 122 µg/m3, respectively. The use of disinfectants was found to increase the TCA concentration in the bathrooms, while the other cleaning products did not. Even though the TCA concentrations were below the WHO’s guideline and the Finnish occupational exposure limit value of 500 µg/m3, the measured TCA levels were occasionally high enough to pose a risk of irritative symptoms. The PM concentrations were low, both in the real-time monitoring (aerodynamic diameter, Dae ≤ 15 µm) and inhalable dust samples (Dae ≤ 100 µm). Highest measured inhalable dust concentration was 350 µg/m3, well below the Finnish occupational limit value of 5,000 µg/m3 for organic inhalable dust.

Funder

Työsuojelurahasto

University of Eastern Finland (UEF) including Kuopio University Hospital

Publisher

Springer Science and Business Media LLC

Subject

Health, Toxicology and Mutagenesis,Management, Monitoring, Policy and Law,Atmospheric Science,Pollution

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3