Abstract
AbstractSwimming pools and spas require a high hygiene level, and therefore constant cleaning. In this study, cleaning workers’ exposure to volatile organic compounds (VOCs), trichloramine (TCA), and particulate matter (PM) in the swimming pools and spas were evaluated. Also, statistical methods were employed to determine what activities affect the exposure to disinfection byproducts (DBPs). The study was conducted in 32 swimming pools and spas. The measurement locations were pool areas, bathrooms, and locker rooms, both during cleaning and opening hours. During the cleaning, the total volatile organic compound (TVOC) concentrations were low, on average 96, 251, and 91 µg/m3 for locker rooms, bathrooms, and pool areas, respectively. Similarly, during the opening hours, the TVOC concentrations were on average 78, 125, and 83 µg/m3, for locker rooms, bathrooms, and pool areas, respectively. This is in line with previous studies investigating cleaning work in other environments. The most prevalent compounds during the cleaning were 2-(2-butoxyethoxy)ethanol (DEGBE), 2-(2-ethoxyethoxy)ethanol (DEGEE), 2-butyl-1-octanol, trichloromethane (chloroform), decamethylcyclopentasiloxane (D5), and carbon tetrachloride. The most prevalent compounds during the opening hours were D5, D-limonene, carbon tetrachloride (bathrooms and pool areas), and trichloromethane (bathrooms and pool areas). The TCA concentrations during the cleaning in the bathrooms and pool areas were on average 60 and 67 µg/m3, respectively, and during the opening hours, 28 and 122 µg/m3, respectively. The use of disinfectants was found to increase the TCA concentration in the bathrooms, while the other cleaning products did not. Even though the TCA concentrations were below the WHO’s guideline and the Finnish occupational exposure limit value of 500 µg/m3, the measured TCA levels were occasionally high enough to pose a risk of irritative symptoms. The PM concentrations were low, both in the real-time monitoring (aerodynamic diameter, Dae ≤ 15 µm) and inhalable dust samples (Dae ≤ 100 µm). Highest measured inhalable dust concentration was 350 µg/m3, well below the Finnish occupational limit value of 5,000 µg/m3 for organic inhalable dust.
Funder
Työsuojelurahasto
University of Eastern Finland (UEF) including Kuopio University Hospital
Publisher
Springer Science and Business Media LLC
Subject
Health, Toxicology and Mutagenesis,Management, Monitoring, Policy and Law,Atmospheric Science,Pollution
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献