AbstractImmiscible carbon dioxide (CO2) injection is one of the highly applied enhanced oil recovery (EOR) methods due to its high oil recovery potential and its ability to store CO2 in the reservoir. The main mechanism of immiscible CO2 injection is oil swelling. Generally, oil swelling is measured experimentally or measured using modeling methods. This research conducts oil swelling experiments using a simplified method in order to easily and accurately measure oil swelling and determines some of the most significant factors that may impact oil swelling during CO2 injection. The impact of varying CO2 injection pressure, temperature, oil viscosity and oil volume on oil swelling capacity was investigated. The simplified method managed to accurately determine the value of oil swelling for all the experiments. One of the factors that was found to impact the method significantly was the oil volume used. The oil volume in the experimental vessel was found to be extremely important since a large oil volume may result in a false oil swelling value. The oil swelling results were compared to other researches and showed that the method applied had an accuracy of over 90% for all the results obtained. This research introduces a simple method that can be used to measure oil swelling and applies this method to investigate some of the factors that may impact the oil swelling capacity during immiscible CO2 injection.