XEN®-45 implantation for refractory uveitic glaucoma

Author:

Evers CharlotteORCID,Anton Alexandra,Böhringer Daniel,Kallee Sara,Keye Philip,Neß Thomas,Philippin Heiko,Reinhard Thomas,Lübke Jan

Abstract

Abstract Purpose To evaluate the efficacy of XEN®-45 gel stent ab interno implantation for medically uncontrolled uveitic glaucoma. Methods Retrospective analysis of 25 eyes receiving XEN® gel stent for medically uncontrolled uveitic glaucoma from February 2019 to February 2023 with recording of intraocular pressure (IOP) values, ocular hypotensive medication, requirement for revision or secondary surgery and complications. Prerequisites for XEN® implantation were a clear cornea, an open iridocorneal angle and an unscarred, mobile conjunctiva at the implantation site. Minimum follow-up required for inclusion was 3 months. The primary outcome measure was IOP compared to baseline. Complete and qualified success were defined as final IOP of ≤ 18 mmHg without or with topical antiglaucomatous treatment, respectively. Failure was defined as IOP > 18 mmHg on two consecutive visits, IOP reduction < 20%, persisting complications from hypotony and open conjunctival bleb revision. Further glaucoma surgical intervention was defined as complete failure. Results Mean preoperative IOP was 35.3 ± 10.9 mmHg on 2.9 ± 0.9 topical antiglaucomatous agents. 19 of 25 patients (76%) received additional oral acetazolamide. 19 eyes were pseudophakic, 5 eyes phakic and 1 aphakic. Early postoperatively, mean IOP reduced to 7.7 ± 3.0 mmHg (75.8% reduction). At final follow-up (mean 17.7 months) mean IOP was 12.0 ± 3.8 mmHg (62.5% reduction) on 0.2 ± 0.6 medications. Six eyes (24%) required bleb revision at mean 28 weeks and therefore were categorized as failure. One eye failed despite bleb revision and restart of topical ocular hypotensive medication. Three other eyes (12%) had IOP spikes with uveitis flare-ups. Transient hypotony complications occurred in 32%. At final follow-up, 18 eyes (72%) achieved complete success and one eye (4%) qualified success. Conclusion The XEN® gel stent effectively reduced IOP in uncontrolled uveitic glaucoma, with 72% complete success. Bleb revision was required in 24%. IOP spikes occurred in 12% despite functioning blebs. Further follow-up is needed to determine long-term outcomes.

Funder

Universitätsklinikum Freiburg

Publisher

Springer Science and Business Media LLC

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Update on Diagnosis and Treatment of Uveitic Glaucoma;Journal of Clinical Medicine;2024-02-20

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3