Digital Leg Volume Quantification: Precision Assessment of a Novel Workflow Based on Single Capture Three-dimensional Whole-Body Surface Imaging
-
Published:2021-09-28
Issue:5
Volume:34
Page:1171-1182
-
ISSN:0897-1889
-
Container-title:Journal of Digital Imaging
-
language:en
-
Short-container-title:J Digit Imaging
Author:
Etzel LucasORCID, Schenck Thilo L., Giunta Riccardo E., Li Zhouxiao, Xu Ya, Koban Konstantin C.
Abstract
AbstractWhole-body three-dimensional surface imaging (3DSI) offers the ability to monitor morphologic changes in multiple areas without the need to individually scan every anatomical region of interest. One area of application is the digital quantification of leg volume. Certain types of morphology do not permit complete circumferential scan of the leg surface. A workflow capable of precisely estimating the missing data is therefore required. We thus aimed to describe and apply a novel workflow to collect bilateral leg volume measurements from whole-body 3D surface scans regardless of leg morphology and to assess workflow precision. For each study participant, whole-body 3DSI was conducted twice successively in a single session with subject repositioning between scans. Paired samples of bilateral leg volume were calculated from the 3D surface data, with workflow variations for complete and limited leg surface visibility. Workflow precision was assessed by calculating the relative percent differences between repeated leg volumes. A total of 82 subjects were included in this study. The mean relative differences between paired left and right leg volumes were 0.73 ± 0.62% and 0.82 ± 0.65%. The workflow variations for completely and partially visible leg surfaces yielded similarly low values. The workflow examined in this study provides a precise method to digitally monitor leg volume regardless of leg morphology. It could aid in objectively comparing medical treatment options of the leg in a clinical setting. Whole-body scans acquired using the described 3DSI routine may allow simultaneous assessment of other changes in body morphology after further validation.
Funder
Ludwig-Maximilians-Universität München
Publisher
Springer Science and Business Media LLC
Subject
Computer Science Applications,Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Reference40 articles.
1. Kroh, A., Peters, F., Alizai, P.H., Schmitz, S., Hölzle, F., Neumann, U.P., Ulmer, F.T., Modabber, A.: 3D optical imaging as a new tool for the objective evaluation of body shape changes after bariatric surgery. Obes. Surg. 30, 1866–1873 (2020). https://doi.org/10.1007/s11695-020-04408-4 2. Ritschl, L.M., Wolff, K.D., Erben, P., Grill, F.D.: Simultaneous, radiation-free registration of the dentoalveolar position and the face by combining 3D photography with a portable scanner and impression-taking. Head Face Med. 15, 1–9 (2019). https://doi.org/10.1186/s13005-019-0212-x 3. Sutherland, J., Belec, J., Sheikh, A., Chepelev, L., Althobaity, W., Chow, B.J.W., Mitsouras, D., Christensen, A., Rybicki, F.J., La Russa, D.J.: Applying modern virtual and augmented reality technologies to medical images and models. J. Digit. Imaging. 32, 38–53 (2019). https://doi.org/10.1007/s10278-018-0122-7 4. Wilting, F.N.H., Hameeteman, M., Tielemans, H.J.P., Ulrich, D.J.O., Hummelink, S.: Three-dimensional evaluation of breast volume changes following autologous free flap breast reconstruction over six months. Breast. 50, 85–94 (2020). https://doi.org/10.1016/j.breast.2020.02.005 5. Koban, K.C., Etzel, L., Li, Z., Pazos, M., Schönecker, S., Belka, C., Giunta, R.E., Schenck, T.L., Corradini, S.: Three-dimensional surface imaging in breast cancer: a new tool for clinical studies? Radiat. Oncol. 15, 1–8 (2020). https://doi.org/10.1186/s13014-020-01499-2
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|