Image distortion correction for MRI in low field permanent magnet systems with strong B0 inhomogeneity and gradient field nonlinearities

Author:

Koolstra KirstenORCID,O’Reilly Thomas,Börnert Peter,Webb Andrew

Abstract

Abstract Objective To correct for image distortions produced by standard Fourier reconstruction techniques on low field permanent magnet MRI systems with strong $${B}_{0}$$ B 0 inhomogeneity and gradient field nonlinearities. Materials and methods Conventional image distortion correction algorithms require accurate $${\Delta B}_{0}$$ Δ B 0 maps which are not possible to acquire directly when the $${B}_{0}$$ B 0 inhomogeneities also produce significant image distortions. Here we use a readout gradient time-shift in a TSE sequence to encode the $${B}_{0}$$ B 0 field inhomogeneities in the k-space signals. Using a non-shifted and a shifted acquisition as input, $$\Delta {B}_{0}$$ Δ B 0 maps and images were reconstructed in an iterative manner. In each iteration, $$\Delta {B}_{0}$$ Δ B 0 maps were reconstructed from the phase difference using Tikhonov regularization, while images were reconstructed using either conjugate phase reconstruction (CPR) or model-based (MB) image reconstruction, taking the reconstructed field map into account. MB reconstructions were, furthermore, combined with compressed sensing (CS) to show the flexibility of this approach towards undersampling. These methods were compared to the standard fast Fourier transform (FFT) image reconstruction approach in simulations and measurements. Distortions due to gradient nonlinearities were corrected in CPR and MB using simulated gradient maps. Results Simulation results show that for moderate field inhomogeneities and gradient nonlinearities, $$\Delta {B}_{0}$$ Δ B 0 maps and images reconstructed using iterative CPR result in comparable quality to that for iterative MB reconstructions. However, for stronger inhomogeneities, iterative MB reconstruction outperforms iterative CPR in terms of signal intensity correction. Combining MB with CS, similar image and $$\Delta {B}_{0}$$ Δ B 0 map quality can be obtained without a scan time penalty. These findings were confirmed by experimental results. Discussion In case of $${B}_{0}$$ B 0 inhomogeneities in the order of kHz, iterative MB reconstructions can help to improve both image quality and $$\Delta {B}_{0}$$ Δ B 0 map estimation.

Funder

European Research Advanced Grant

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology,Biophysics

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3