Evaluation of the Dose Delivery Consistency and Its Dependence on Imaging Modality and Deformable Image Registration Algorithm in Prostate Cancer Patients
Author:
Publisher
Springer Science and Business Media LLC
Subject
Biomedical Engineering,General Medicine
Link
https://link.springer.com/content/pdf/10.1007/s40846-021-00673-5.pdf
Reference26 articles.
1. Mavroidis, P., Ferreira, B. C., Papanikolaou, N., Svensson, R., Kappas, C., Lind, B. K., & Brahme, A. (2006). Assessing the difference between planned and delivered intensity-modulated radiotherapy dose distributions based on radiobiological measures. Clinical Oncologia, 18, 529–538.
2. Veiga, C., McClelland, J., Mouinuddin, S., Lourenço, A., Ricketts, K., Annkah, J., Modat, M., Ourselin, S., D’Souza, D., & Royle, G. (2014). Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for “dose of the day” calculations. Medical Physics, 41, 031703.
3. Boda-Heggemann, J., Lohr, F., Wenz, F., Flentje, M., & Guckenberger, M. (2011). kV cone-beam CT-based IGRT: A clinical review. Strahlentherapie und Onkologie, 187, 284–291.
4. Hamilton, C. S., & Ebert, M. A. (2005). Volumetric uncertainty in radiotherapy. Clinical Oncology (Royal College of Radiologist), 17, 456–464.
5. Kapatoes, J. M., Olivera, G. H., Ruchala, K. J., & Mackie, T. R. (2001). On the verification of the incident energy fluence in tomotherapy IMRT. Physics in Medical and Biology, 46, 2953–2965.
Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Contour‐guided deep learning based deformable image registration for dose monitoring during CBCT‐guided radiotherapy of prostate cancer;Journal of Applied Clinical Medical Physics;2023-05-25
2. Effectiveness of CT‐image guidance in proton therapy for liver cancer and the importance of daily dose monitoring for tumors and organs at risk;Medical Physics;2023-04-26
3. Evaluation of the clinical impact of the differences between planned and delivered dose in prostate cancer radiotherapy based on CT‐on‐rails IGRT and patient‐reported outcome scores;Journal of Applied Clinical Medical Physics;2022-09-10
1.学者识别学者识别
2.学术分析学术分析
3.人才评估人才评估
"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370
www.globalauthorid.com
TOP
Copyright © 2019-2024 北京同舟云网络信息技术有限公司 京公网安备11010802033243号 京ICP备18003416号-3