Intraoperative imaging and navigated spinopelvic instrumentation: S2-alar-iliac screws combined with tricortical S1 pedicle screw fixation

Author:

Sargut Tarik Alp,Hecht Nils,Xu Ran,Bohner Georg,Czabanka Marcus,Stein Julia,Richter Marcus,Bayerl Simon,Woitzik Johannes,Vajkoczy Peter

Abstract

Abstract Purpose The present study aimed to assess the feasibility, safety and accuracy of navigated spinopelvic fixation with focus on S2-alar-iliac screws (S2AIS) and tricortical S1 pedicle screw implantation with the use of high-resolution three-dimensional intraoperative imaging and real-time spinal navigation. Methods Patients undergoing navigated intraoperative CT-based spinopelvic stabilization between January 2016 and September 2019 were included. Pelvic fixation was achieved by implantation of S2AIS or iliac screws (IS). S1 screws were implanted with the goal of achieving tricortical purchase. In all cases, instrumentation was performed with real-time spinal navigation and intraoperative screw positioning was assessed using intraoperative computed tomography (iCT), cone-beam CT (CBCT) and robotic cone-beam CT (rCBCT). Screw accuracy was evaluated based on radiographic criteria. To identify predictors of complications, univariate analysis was performed. Results Overall, 52 patients (85%) received S2AIS and nine patients (15%) received IS instrumentation. Intraoperative imaging and spinal navigation were performed with iCT in 34 patients, CBCT in 21 patients and rCBCT in six patients. A total number of 10/128 (7.8%) iliac screws underwent successful intraoperative correction due to misalignment. Tricortical purchase was successfully accomplished in 58/110 (53%) of the S1 screws with a clear learning curve in the course of time. S2AIS implantation was associated with significantly fewer surgical side infection-associated surgeries. Conclusions Real-time navigation facilitated spinopelvic instrumentation with increasing accuracy of S2AIS and tricortical S1 screws. Intraoperative imaging by iCT, CBCT or rCBCT permitted screw assessment with the chance of direct navigated revision of misplaced iliac screws to avoid secondary screw revision surgery.

Funder

Charité - Universitätsmedizin Berlin

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3