Author:
Wilke Hans-Joachim,Kienle Annette,Maile Sebastian,Rasche Volker,Berger-Roscher Nikolaus
Abstract
Abstract
Purpose
The cause of disc herniation is not well understood yet. It is assumed that heavy lifting and extreme postures can cause small injuries starting either in the inner anulus or from the outside close to the endplate. Such injuries are accumulated over years until its structure is weakened and finally a single loading event leads to a sudden failure of the last few intact lamellae. This paper describes a novel, custom-developed dynamic 6-DOF disc-loading simulator that allows complex loading to provoke such disc damage and herniations.
Methods
The machine’s axes are driven by six independent servomotors providing high loads (10 kN axial compression, 2 kN shear, 100 Nm torque) up to 5 Hz. A positional accuracy test was conducted to validate the machine. Subsequently, initial experiments with lumbar ovine motion segments under complex loading were performed. After testing, the discs were examined in an ultra-high field MRI (11.7 T). A three-dimensional reconstruction was performed to visualise the internal disc lesions.
Results
Validation tests demonstrated positioning with an accuracy of ≤0.08°/≤0.026 mm at 0.5 Hz and ≤0.27°/≤0.048 mm at 3.0 Hz with amplitudes of ±17°/±2 mm. Typical failure patterns and herniations could be provoked with complex asymmetrical loading protocols. Loading with axial compression, flexion, lateral bending and torsion lead in 8 specimens to 4 herniated discs, two protrusions and two delaminations. All disc failures occurred in the posterior region of the disc.
Conclusion
This new dynamic disc-loading simulator has proven to be able to apply complex motion combinations and allows to create artificial lesions in the disc with complex loading protocols. The aim of further tests is to better understand the mechanisms by which disc failure occurs at the microstructural level under different loading conditions. Visualisation with ultra-high field MRI at different time points is a promising method to investigate the gradual development of such lesions, which may finally lead to disc failure. These kinds of experiments will help to better investigate the mechanical failure of discs to provide new insights into the initiation of intervertebral disc herniation. This device will also serve for many other applications in spine biomechanics research.
Funder
German Research Foundation
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Reference58 articles.
1. Kanna RM, Shetty AP, Rajasekaran S (2014) Patterns of lumbar disc degeneration are different in degenerative disc disease and disc prolapse magnetic resonance imaging analysis of 224 patients. Spine J 14(2):300–307. doi:10.1016/j.spinee.2013.10.042
2. Andersson G (1997) Epidemiology of spinal disorders. In: Frymoyer JW, Ducker TB, Hadler NM, Kostuik JP, Weinstein JN, Whitecloud TSI (eds) The adult spine: principles and practice. Raven Press, New York, pp 93–141
3. Federal Statistical Office of Germany (2012) Health monitoring information system—diagnostic data (ICD 10: M51.0-51.2). http://www.gbe-bund.de
4. Postacchini F, Cinotti G (1999) Etiopathogenesis. In: Postacchini F (ed) Lumbar disc herniation. Springer, Wien, pp 151–164, 629
5. White AAI, Panjabi MM (1990) Clinical biomechanics of the spine. J.B. Lippincott Company, Philadelphia
Cited by
45 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献