Ultra-high resolution 3D MRI for chondrocalcinosis detection in the knee—a prospective diagnostic accuracy study comparing 7-tesla and 3-tesla MRI with CT

Author:

Germann ChristophORCID,Galley Julien,Falkowski Anna L.,Fucentese Sandro F.,Pfirrmann Christian W. A.,Nanz Daniel,Sutter Reto

Abstract

Abstract Objectives To test the diagnostic accuracy of a 3D dual-echo steady-state (DESS) sequence at 7-T MRI regarding the detection of chondral calcific deposits of the knee in comparison to 3-T MRI, using CT as cross-sectional imaging reference standard. Methods CT and 7-T MRI (DESS) of knee joints in 42 patients with radiographically known chondrocalcinosis (13 of 42 bilateral) were prospectively acquired for all included patients (n = 55 knee joints). Additionally, 3-T MRI (DESS) was performed for 20 of these 55 knee joints. Two fellowship-trained musculoskeletal radiologists scored eight cartilage regions of each knee joint separately regarding presence of cartilage calcification, diagnostic confidence level, and sharpness of calcific deposits. In an explorative subanalysis, micro-CT of the menisci was evaluated after knee arthroplasty in one patient. Diagnostic performance metrics and nonparametric tests were used to compare between modalities. p values < 0.05 were considered to represent statistical significance. Results Sensitivity for chondrocalcinosis detection was significantly higher for 7-T MRI (100%) compared to 3-T MRI (reader 1: 95.9%, p = 0.03; reader 2: 93.2%, p = 0.002). The diagnostic confidence was significantly higher for both readers at 7 T compared to both 3-T MRI (p < 0.001) and to CT (p = 0.03). The delineation of chondral calcifications was significantly sharper for 7-T compared to both 3-T MRI and CT (p < 0.001, both readers). Micro-CT in one patient suggested that 7-T MRI may potentially outperform standard CT in diagnosing chondral calcifications. Conclusion 3D-DESS imaging at 7-T MRI offers a significantly higher sensitivity in detection of chondral calcific deposits compared to 3-T MRI. Key Points • 3D dual-echo steady-state (DESS) MRI at 7 T has a higher sensitivity in detection of chondral calcific deposits compared to 3-T MRI (p ≤ 0.03). • 3D DESS MRI at 7 T yields no false-negative cases regarding presence of chondral calcific deposits. • 3D DESS MRI at 7 T offers better delineation and higher diagnostic confidence in detection of chondral calcific deposits compared to 3-T MRI (p < 0.001).

Funder

Universität Zürich

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3