Cadaveric study of ergonomics and performance using a robotic exoscope with a head-mounted display in spine surgery

Author:

Demetz Matthias,Abramovic Anto,Krigers Aleksandrs,Bauer Marlies,Lener Sara,Pinggera Daniel,Kerschbaumer Johannes,Hartmann Sebastian,Fritsch Helga,Thomé Claudius,Freyschlag Christian F.

Abstract

AbstractThe conventional microscope has the disadvantage of a potentially unergonomic posture for the surgeon, which can affect performance. Monitor-based exoscopes could provide a more ergonomic posture, as already shown in pre-clinical studies. The aim of this study was to test the usability and comfort of a novel head-mounted display (HMD)-based exoscope on spinal surgical approaches in a simulated OR setting. A total of 21 neurosurgeons naïve to the device were participated in this prospective trial. After a standardized training session with the device, participants were asked to perform a single-level thoracolumbar decompression surgery on human cadavers using the exoscope. Subsequently, all participants completed a comfort and safety questionnaire. For the objective evaluation of the performance, all interventions were videotaped and analyzed. Twelve men and nine women with a mean age of 34 (range: 24–57) were participating in the study. Average time for decompression was 15 min (IqR 9.6; 24.2); three participants (14%) terminated the procedure prematurely. In these dropouts, a significantly higher incidence of back/neck pain (p = 0.002 for back, p = 0.046 for neck pain) as well as an increased frequency of HMD readjustments (p = 0.045) and decreased depth perception (p = 0.03) were documented. Overall, the surgeons’ satisfaction with the exoscope was 84% (IqR 75; 100). Using a standardized, pre-interventional training, it is possible for exoscope-naïve surgeons to perform sufficient spinal decompression using the HMD-based exoscope with a high satisfaction. However, inaccurate HMD setup prior to the start of the procedure may lead to discomfort and unsatisfactory results.

Funder

University of Innsbruck and Medical University of Innsbruck

Publisher

Springer Science and Business Media LLC

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3