Abstract
AbstractThis paper presents experimental and numerical results of an investigation into the thermal and structural behaviour of an innovative modular structural steel system, which includes cellular beams, that was tested in a 1-h standard fire scenario while loaded. The modular system consists of a 5.66 × 3.8 m rectangular steel frame, with a profiled steel sandwich decking (SD) system attached, which comprises of (a) profiled steel decking, (b) fibre cement, and (c) calcium silicate boards and strips. The SD system is suspended from the underside of the horizontal structural members to provide inherent fire protection to the steel beams from the bottom and acts as the load-bearing component of the flooring. The purpose of the experiment was to determine the fire resistance of the structural system, whilst under load, which is primarily based on the fire resistance of the SD system. Temperature data for the SD system was collected during the experiment and used to validate a numerical finite element analysis model. This study shows that the SD system was able to achieve a fire resistance rating of 57 min in the experiment which was governed by insulation resistance. A lower fire resistance rating is estimated based on numerical models. Structural resistance was maintained throughout the test. During preliminary testing structural collapse was observed in a separate experiment which highlights how the system is sensitive to damage to the ceiling boards. Numerical results highlight that thermal bowing and movement may result in changes in thermal interactions between adjacent elements. This paper provides novel large-scale experimental data on a loaded flooring system in fire.
Funder
Ministry of Economy, Trade and Industry
Stellenbosch University
Publisher
Springer Science and Business Media LLC
Subject
Safety, Risk, Reliability and Quality,General Materials Science,Building and Construction
Reference44 articles.
1. Wright HD, Evans HR, Burt CA (1989) Profiled steel sheet/dry boarding composite floors. Struct Eng A 67:114–120
2. Jahan A (2018) Axial and shear behavior of profiled steel sheet dry board (Pssdb) composite walling system
3. Awang H, Badaruzzaman W (2011) Development of profiled steel sheeting dry board roof panel system in school classroom modules. J Civ Eng Constr Technol 2:72–81
4. Badaruzzaman W, Ahmed E, Rashid A (1996) Behaviour of profiled steel sheet dry board system. In: Beijing International Conference, pp 21–24
5. Wan Badaruzzaman WH, Zain MFM, Akhand AM, Ahmed E (2003) Dry boards as load bearing element in the profiled steel sheet dry board floor panel system—structural performance and applications. Constr Build Mater 17:289–297. https://doi.org/10.1016/S0950-0618(02)00105-8
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献