Accuracy of a Low-Cost Continuous Subcutaneous Insulin Infusion Pump Prototype: In Vitro Study Using Combined Methodologies
Author:
Funder
Fundação de Amparo à Pesquisa do Estado de São Paulo
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Publisher
Springer Science and Business Media LLC
Subject
Biomedical Engineering
Link
https://link.springer.com/content/pdf/10.1007/s10439-020-02721-8.pdf
Reference44 articles.
1. ABNT, N. IEC 60601-2-24: Requisitos particulares para a segunrança básica e o desempenho essencial de bombas de infusão e de controladores de infusão, 2005.
2. Balda, C. A., and A. Pacheco-Silva. Artigo de Revisão Aspectos imunológicos do diabetes melito tipo 1. Rev Ass Med Bras. 45:175–180, 1999.
3. Borot, S., S. Franc, J. Cristante, A. Penfornis, P. Y. Benhamou, B. Guerci, H. Hanaire, E. Renard, Y. Reznik, C. Simon, and G. Charpentier. Accuracy of a new patch pump based on a microelectromechanical system (MEMS) compared to other commercially available insulin pumps: Results of the first in vitro and in vivo studies. J. Diabetes Sci. Technol. 8:1133–1141, 2014.
4. Bowen, J. L., and C. J. Allender. A comparative pulse accuracy study of two commercially available patch insulin infusion pumps. Eur. Endocrinol. 12:79–84, 2016.
5. Breton, M. D., and B. P. Kovatchev. Impact of blood glucose self-monitoring errors on glucose variability, risk for hypoglycemia, and average glucose control in type 1 diabetes: An in silico study. J. Diabetes Sci. Technol. 4:562–570, 2010.
Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Recent advances in the precision control strategy of artificial pancreas;Medical & Biological Engineering & Computing;2024-02-28
2. Insulin infusion sets associated with adverse events: strategies for improved diabetes education;Frontiers in Medicine;2023-11-29
3. The Relationship Between Different Bench Test Methodologies and Accuracy of Insulin Infusion Pumps: A Systematic Literature Review;Annals of Biomedical Engineering;2022-08-11
4. Risk Management of a Low-cost Insulin Infusion Pump: A Case Study with a Brazilian Company;2021 IEEE 34th International Symposium on Computer-Based Medical Systems (CBMS);2021-06
5. The separation of insulin pump hardware and software - a novel and low-cost approach to insulin pump design;IFAC-PapersOnLine;2021