Assessing setting times of cementitious materials using semi-adiabatic calorimetry

Author:

Baranyi Attila,Kopecskó KatalinORCID,Csetényi László

Abstract

AbstractThe most common methods for the determination of setting times of cements are the various penetration tests. One of the most important of these is the Vicat method, which is the current standard measurement (EN 196-3) to determine the setting time of cement. However, there are alternative methods that can be used to monitor the setting process and eliminate several issues that arise from the Vicat method, such as intermittent measurement, measurability of cement pastes of non-standard consistency, testing mortars and concretes.One such method is semi-adiabatic calorimetry (SAC), which can be an alternative to penetration tests in appropriate circumstances. In this study, determination of setting times of two sources of CEM I 42.5 N cement was observed, using semi-adiabatic calorimetry at different (0.25; 0.27; 0.29; and, 0.31) water to cement ratios (w/c). During our measurements, we observed that the ratio between the setting time of a given source of cement and the time it took to reach the maximum rate of heat development was almost constant for the same cement and w/c ratio, which enables a simple and inexpensive routine measurement of setting times of Portland cement.

Funder

Budapest University of Technology and Economics

Publisher

Springer Science and Business Media LLC

Reference31 articles.

1. EN 196–3:2016. Methods of testing cement. Determination of setting times and soundness. ISBN: 978 0 580 93547 3

2. Double DD, Hellawell A, S. Perry SJ. The hydration of Portland cement. Proceedings of the Royal Society of London. A, Mathematical and Physical Sciences. 1978; 359(1699):435–451. https://doi.org/10.1098/rspa.1978.0050

3. Bensted J. Some applications of conduction calorimetry to cement hydration. Adv Cem Res. 1987;1(1):35–44. https://doi.org/10.1680/adcr.1987.1.1.35.

4. Egan PJ. A comparison between semi-isothermal and semi-adiabatic calorimetry of retarded cement mixes. Adv Cem Res. 1988;1(2):112–8. https://doi.org/10.1680/adcr.1988.1.2.112.

5. Wang K, Ge Z, Grove J, Ruiz JM, Rasmussen R, Ferragut T. Developing a simple and rapid test for monitoring the heat evolution of concrete mixtures for both laboratory and field applications. Institute for Transportation Project Reports. 2007;153. http://lib.dr.iastate.edu/intrans_reports/153