Reduction of detection limits in monitoring of internal exposures by a combined evaluation of emissions and spectra

Author:

Meisenberg OliverORCID

Abstract

AbstractRoutine monitoring of internal exposures requires the detection of effective doses of at most 1 mSv per calendar year. For some radionuclides, this requirement cannot be satisfied by a conventional evaluation of the spectra that are gained in alpha or gamma spectrometry. However, since several measurements are conducted per calendar year on a regular basis, a combined evaluation of measurements, i.e. the evaluation of sum spectra, is possible. Additionally, radionuclides that feature several emissions of alpha or gamma radiation allow a combined evaluation of their emissions. Both methods can lead to significantly smaller detection limits as compared to a separate evaluation of spectra in many cases. However, the variation of parameters that influence the evaluation such as the measurement efficiency, abundance and chemical yield requires specific calculations and treatments of the spectra as well as a manipulation of the channel contents: In a combination of emissions, energy regions are summed and evaluated with a combined efficiency that is weighted by the abundances. In a combination of spectra, the channel contents must be scaled by the ratio of the calibration factors before the summation of the spectra. In the routine monitoring of short-lived radionuclides that feature a variety of emissions such as 225Ac, these combinations are particularly effective in reducing the detectable annual effective dose. For alpha spectrometry of 225Ac, both methods applied together can lead to a detectable effective dose of about 1 mSv per year as compared to a dose of about 90 mSv with a conventional separate evaluation.

Funder

Bundesamt für Strahlenschutz

Publisher

Springer Science and Business Media LLC

Reference17 articles.

1. Advanced Measurement Technology, Inc. (Ortec) (2020) GammaVision, Maestro-PRO, Gamma-Ray Spectrum Analysis and MCA emulators for Microsoft Windows 7, 8.1, and 10 Professional. Software User’s Manual, Software Version 9, Manual Revision M. Chapter 6.17.3.6.

2. Arndt R, Hummrich H, Kandzia F, Kunze C, Lucks C, Hoeppener-Kramar U, Fritz G (2023) Verification of the calculation of characteristic limits according to DIN EN ISO 11929 in common spectroscopy software (Überprüfung Der Berechnung charakteristischer Grenzen Nach DIN EN ISO 11929 in verbreiteter Spektrometrie-Software, in German). Federal Office for Radiation Protection (ed.), Salzgitter

3. Barker E, Cagnat X, Bouisset P, Mekhlouche D, Aubry S, Gurriaran R (2005) Summing spectra in gamma spectrometry for improving detection of low-level radionuclides in aerosol samples. Radioprotection 40:S733–S737

4. Canberra Industries, Inc (2023) CAM Files. In: Genie 2000 Spectroscopy Software, Customization Tools, V4.0

5. Canberra Industries, Inc (2009) Model S561 Genie 2000 Batch Tools Support, V1.4

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3