CT-based patient-specific instrumentation for total knee arthroplasty in over 700 cases: single-use instruments are as accurate as standard instruments

Author:

Gaukel StefanORCID,Vuille-dit-Bille Raphael N.,Schläppi Michel,Koch Peter P.

Abstract

Abstract Purpose Efforts in total knee arthroplasty are made to improve accuracy for a correct leg axis and reduce component malpositioning using patient-specific instruments. It was hypothesized that use of patient-specific instruments (vs. computer-navigated and conventional techniques) will reduce the number of outliers. Our second hypothesis was that single-use instrumentation will lead to the same accuracy compared to patient-specific instruments made of metal. Methods 708 primary total knee arthroplasties between 2014 and 2018 using computer tomography (CT)-based patient-specific cutting block technique and a preoperative planning protocol were retrospectively reviewed. Preoperative data [hip–knee–angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), tibial slope, femoral component flexion] was compared to postoperative performed standard radiological follow-up X-rays. Differences of > 3° between measurements were defined as outliers. Results Overall 500 prostheses using standard instrumentation and 208 prostheses using single-use instruments were implanted. Preoperative HKA axes (− 1.2°; p < 0.001), femoral component flexion (Δ 0.8°, p < 0.001), LDFA (Δ − 1.5°, p < 0.001), MPTA (Δ − 0.5°, p < 0.001) and tibial posterior slopes (Δ 0.5°, p < 0.001), respectively, were different from postoperative axes. More outliers occurred using standard (vs. single-use) instruments (p < 0.001) regarding postoperative HKA (ranges of standard- vs. single-use: instruments: HKA 178.0°–180.5° vs. 178.0°–180.5°, femoral component flexion 0.0°–6.0° vs. 0.0°–4.5°, LDFA 90.0°–91.0° vs. 90.0°–90.0°, MPTA 90.0°–90.0° vs. 90.0°–90.0°, tibial posterior slope − 10° to 10° vs. − 1° to 10°). No differences were seen for other angles measured. Comparing both systems, total number of outliers was higher using standard (8%) vs. single-use instruments (4.3%). Conclusion This study shows a high accuracy of CT-based patient-specific instrumentation concerning postoperative achieved knee angles and mechanical leg axes. Single-use instruments showed a similar accuracy. Level of evidence III.

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3