No kinematical difference between ultra-congruent and medial-congruent total knee arthroplasty when implanted with mechanical alignment: an in vivo dynamic RSA study

Author:

Alesi Domenico,Di Paolo Stefano,Bragonzoni Laura,Pizza Nicola,Zaffagnini Stefano,Zinno Raffaele,Marcheggiani Muccioli Giulio Maria

Abstract

Abstract Purpose To explore in vivo kinematical behavior of the same total knee arthroplasty (TKA) cruciate-retaining (CR) femoral design with either medial-congruent (MC) or ultra-congruent (UC) inlay using model-based dynamic radiostereometric analysis (RSA). The hypothesis was that there would be comparable kinematics between the two groups. Methods A cohort of 16 randomly selected patients (8 MC Persona Zimmer, 8 UC Persona Zimmer) was evaluated through dynamic radiostereometric analysis (RSA) at a minimum of 9 months after TKA, during the execution of a sit-to-stand. The antero-posterior (AP) translation of the femoral component and the AP translation of the low point of medial and lateral femoral compartments were compared through Student’s t test (p < 0.05). Results Both groups showed a medial pivot behavior, with a significantly greater anterior translation of the Low Point of the lateral compartment with respect to the medial compartment (MC medial range: 2.4 ± 2.4 mm; MC lateral range: 7.7 ± 3.0 mm; p < 0.001 – UC medial range: 3.3 ± 3.3 mm; UC lateral range: 8.0 ± 3.2 mm; p < 0.001). A statistically significant greater degree of flexion was clinically recorded at follow-up visit in the MC group respect to the UC group (126° vs 101°—p = 0.003). Conclusion The present study did not show difference in the medial pivot behavior between ultra-congruent and medial-congruent total knee arthroplasty when implanted with mechanical alignment; however, the MC group demonstrated a greater degree of flexion. The MC design examined is a valid alternative to the UC design, allowing to achieve a screw-home movement restoration combined with a high flexion. Level of evidence IV.

Funder

Alma Mater Studiorum - Università di Bologna

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3