Harmonisation of PET/CT contrast recovery performance for brain studies

Author:

Verwer E. E.,Golla S. S. V.,Kaalep A.,Lubberink M.,van Velden F. H. P.,Bettinardi V.,Yaqub M.,Sera T.,Rijnsdorp S.,Lammertsma A. A.,Boellaard R.

Abstract

Abstract Purpose In order to achieve comparability of image quality, harmonisation of PET system performance is imperative. In this study, prototype harmonisation criteria for PET brain studies were developed. Methods Twelve clinical PET/CT systems (4 GE, 4 Philips, 4 Siemens, including SiPM-based “digital” systems) were used to acquire 30-min PET scans of a Hoffman 3D Brain phantom filled with ~ 33 kBq·mL−1 [18F]FDG. Scan data were reconstructed using various reconstruction settings. The images were rigidly coregistered to a template (voxel size 1.17 × 1.17 × 2.00 mm3) onto which several volumes of interest (VOIs) were defined. Recovery coefficients (RC) and grey matter to white matter ratios (GMWMr) were derived for eroded (denoted in the text by subscript e) and non-eroded grey (GM) and white (WM) matter VOIs as well as a mid-phantom cold spot (VOIcold) and VOIs from the Hammers atlas. In addition, left-right hemisphere differences and voxel-by-voxel differences compared to a reference image were assessed. Results Systematic differences were observed for reconstructions with and without point-spread-function modelling (PSFON and PSFOFF, respectively). Normalising to image-derived activity, upper and lower limits ensuring image comparability were as follows: for PSFON, RCGMe = [0.97–1.01] and GMWMre = [3.51–3.91] for eroded VOI and RCGM = [0.78–0.83] and GMWMr = [1.77–2.06] for non-eroded VOI, and for PSFOFF, RCGMe = [0.92–0.99] and GMWMre = [3.14–3.68] for eroded VOI and RCGM = [0.75–0.81] and GMWMr = [1.72–1.95] for non-eroded VOI. Conclusions To achieve inter-scanner comparability, we propose selecting reconstruction settings based on RCGMe and GMWMre as specified in “Results”. These proposed standards should be tested prospectively to validate and/or refine the harmonisation criteria.

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3