Phantom and clinical evaluation of the Bayesian penalised likelihood reconstruction algorithm Q.Clear without PSF correction in amyloid PET images

Author:

Wagatsuma KeiORCID,Sakata Muneyuki,Miwa Kenta,Hamano Yumi,Kawakami Hirofumi,Kamitaka Yuto,Yamao Tensho,Miyaji Noriaki,Ishibashi Kenji,Tago Tetsuro,Toyohara Jun,Ishii Kenji

Abstract

Abstract Purpose Bayesian penalised likelihood (BPL) reconstruction, which incorporates point-spread-function (PSF) correction, provides higher signal-to-noise ratios and more accurate quantitation than conventional ordered subset expectation maximization (OSEM) reconstruction. However, applying PSF correction to brain PET imaging is controversial due to Gibbs artefacts that manifest as unpredicted cortical uptake enhancement. The present study aimed to validate whether BPL without PSF would be useful for amyloid PET imaging. Methods Images were acquired from Hoffman 3D brain and cylindrical phantoms for phantom study and 71 patients administered with [18F]flutemetamol in clinical study using a Discovery MI. All images were reconstructed using OSEM, BPL with PSF correction, and BPL without PSF correction. Count profile, %contrast, recovery coefficients (RCs), and image noise were calculated from the images acquired from the phantoms. Amyloid β deposition in patients was visually assessed by two physicians and quantified based on the standardised uptake value ratio (SUVR). Results The overestimated radioactivity in profile curves was eliminated using BPL without PSF correction. The %contrast and image noise decreased with increasing β values in phantom images. Image quality and RCs were better using BPL with, than without PSF correction or OSEM. An optimal β value of 600 was determined for BPL without PSF correction. Visual evaluation almost agreed perfectly (κ = 0.91–0.97), without depending on reconstruction methods. Composite SUVRs did not significantly differ between reconstruction methods. Conclusion Gibbs artefacts disappeared from phantom images using the BPL without PSF correction. Visual and quantitative evaluation of [18F]flutemetamol imaging was independent of the reconstruction method. The BPL without PSF correction could be the standard reconstruction method for amyloid PET imaging, despite being qualitatively inferior to BPL with PSF correction for [18F]flutemetamol amyloid PET imaging.

Funder

Japan Society for the Promotion of Science

Publisher

Springer Science and Business Media LLC

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3