No impact of attenuation and scatter correction on the interpretation of dopamine transporter SPECT in patients with clinically uncertain parkinsonian syndrome

Author:

Schiebler Tassilo,Apostolova Ivayla,Mathies Franziska Lara,Lange Catharina,Klutmann Susanne,Buchert RalphORCID

Abstract

Abstract   Purpose The benefit from attenuation and scatter correction (ASC) of dopamine transporter (DAT)-SPECT for the detection of nigrostriatal degeneration in clinical routine is still a matter of debate. The current study evaluated the impact of ASC on visual interpretation and semi-quantitative analysis of DAT-SPECT in a large patient sample. Methods One thousand seven hundred forty consecutive DAT-SPECT with 123I-FP-CIT from clinical routine were included retrospectively. SPECT images were reconstructed iteratively without and with ASC. Attenuation correction was based on uniform attenuation maps, scatter correction on simulation. All SPECT images were categorized with respect to the presence versus the absence of Parkinson-typical reduction of striatal 123I-FP-CIT uptake by three independent readers. Image reading was performed twice to assess intra-reader variability. The specific 123I-FP-CIT binding ratio (SBR) was used for automatic categorization, separately with and without ASC. Results The mean proportion of cases with discrepant categorization by the same reader between the two reading sessions was practically the same without and with ASC, about 2.2%. The proportion of DAT-SPECT with discrepant categorization without versus with ASC by the same reader was 1.66% ± 0.50% (1.09–1.95%), not exceeding the benchmark of 2.2% from intra-reader variability. This also applied to automatic categorization of the DAT-SPECT images based on the putamen SBR (1.78% discrepant cases between without versus with ASC). Conclusion Given the large sample size, the current findings provide strong evidence against a relevant impact of ASC with uniform attenuation and simulation-based scatter correction on the clinical utility of DAT-SPECT to detect nigrostriatal degeneration in patients with clinically uncertain parkinsonian syndrome.

Funder

Universitätsklinikum Hamburg-Eppendorf (UKE)

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3