Automated identification of uncertain cases in deep learning-based classification of dopamine transporter SPECT to improve clinical utility and acceptance

Author:

Budenkotte Thomas,Apostolova Ivayla,Opfer Roland,Krüger Julia,Klutmann Susanne,Buchert RalphORCID

Abstract

Abstract Purpose Deep convolutional neural networks (CNN) are promising for automatic classification of dopamine transporter (DAT)-SPECT images. Reporting the certainty of CNN-based decisions is highly desired to flag cases that might be misclassified and, therefore, require particularly careful inspection by the user. The aim of the current study was to design and validate a CNN-based system for the identification of uncertain cases. Methods A network ensemble (NE) combining five CNNs was trained for binary classification of [123I]FP-CIT DAT-SPECT images as “normal” or “neurodegeneration-typical reduction” with high accuracy (NE for classification, NEfC). An uncertainty detection module (UDM) was obtained by combining two additional NE, one trained for detection of “reduced” DAT-SPECT with high sensitivity, the other with high specificity. A case was considered “uncertain” if the “high sensitivity” NE and the “high specificity” NE disagreed. An internal “development” dataset of 1740 clinical DAT-SPECT images was used for training (n = 1250) and testing (n = 490). Two independent datasets with different image characteristics were used for testing only (n = 640, 645). Three established approaches for uncertainty detection were used for comparison (sigmoid, dropout, model averaging). Results In the test data from the development dataset, the NEfC achieved 98.0% accuracy. 4.3% of all test cases were flagged as “uncertain” by the UDM: 2.5% of the correctly classified cases and 90% of the misclassified cases. NEfC accuracy among “certain” cases was 99.8%. The three comparison methods were less effective in labelling misclassified cases as “uncertain” (40–80%). These findings were confirmed in both additional test datasets. Conclusion The UDM allows reliable identification of uncertain [123I]FP-CIT SPECT with high risk of misclassification. We recommend that automatic classification of [123I]FP-CIT SPECT images is combined with an UDM to improve clinical utility and acceptance. The proposed UDM method (“high sensitivity versus high specificity”) might be useful also for DAT imaging with other ligands and for other binary classification tasks.

Funder

Bundesministerium für Wirtschaft und Klimaschutz

Universitätsklinikum Hamburg-Eppendorf (UKE)

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3