Author:
González Vicente Gutiérrez,Bandera Carlos Fernández
Abstract
AbstractNowadays, building energy models (BEMs) are widely used, particularly in the assessment of energy consumption in buildings to address the potential savings that can be generated. The realisation of a dynamic energy model based on high-fidelity physics (white-box models) requires a tuning process to fit the model to reality, due to many uncertainties involved. Currently some research trends try to reduce this performance gap by modulating different types of experimental parameters such as: capacitances or infiltration. The EnergyPlus simulation software, in its latest versions, has implemented an object: HybridModel:Zone that calculates the infiltration and internal mass of buildings using an inverse modelling approach that employs only the measured indoor temperature data to invert the heat balance equation for the zone under study. The main objective of this paper is to reduce the execution time and uncertainties in the development of quality energy models by generating a new calibration methodology that implements this approach. This uses, as a starting point, a research created by the authors of this study, which was empirically and comparatively validated against the energy models developed by the participants in Annex 58. It is also worth highlighting the empirical validation of the HybridModel:Zone object, since it was activated in all scenarios where its execution is possible: periods of seven days or more of free oscillation and periods in which the building is under load. The findings are promising. The data generated with the new methodology, if compared with those produced by the baseline model, improve their resemblance to the real ones by 22.9%. While those of its predecessor did it by 15.6%. For this study, the two dwellings foreseen in Annex 58 of the IEA ECB project have been modelled and their real monitoring data have been used.
Publisher
Springer Science and Business Media LLC
Subject
Energy (miscellaneous),Building and Construction
Reference57 articles.
1. Al-Homoud MS (2001). Computer-aided building energy analysis techniques. Building and Environment, 36: 421–433.
2. Annex58 (2016). Annex 58: Reliable building energy performance characterisation based on full scale dynamic measurement. Available at https://bwk.kuleuven.be/bwf/projects/annex58/index.htm. Accessed 10-06-2020.
3. Ascione F, Bianco N, Iovane T, et al. (2020). A real industrial building: Modeling, calibration and Pareto optimization of energy retrofit. Journal of Building Engineering, 29: 101186.
4. ASHRAE (2013). ASHRAE Handbook: Fundamentals. Atlanta, GA, USA: The American Society of Heating, Refrigerating and Air-Conditioning Engineers.
5. Burch J, Subbarao K, Lekov A, et al. (1990). Short-term energy monitoring in a large commercial building. ASHRAE Transactions, 96(1): 1459–1477, 1990.
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献