Assessing Spatiotemporal Behavior of Human Gait: A Comparative Study Between Low-Cost Smartphone-Based Mocap and OptiTrack Systems

Author:

Castillo B.,Riascos C.,Franco J. M.,Marulanda J.,Thomson P.

Abstract

AbstractThis study assessed the accuracy of a low-cost marker-based motion capture system with smartphone devices to estimate the spatiotemporal behavior of human gait in comparison with the performance of the commercial OptiTrack system. Initially, three test subjects were selected for the study, and after equipping them with passive retroreflective markers, they were recorded for gait velocities of 1.50, 1.90, and 2.30 $$m\bullet {s}^{-1}$$ m s - 1 while collecting kinematic data and videos. The results showed that the smartphone motion capture system exhibited significant spatiotemporal tracking and accuracy in the x-y trajectories and estimation of joint relative angles of the hip, knee, and ankle joints (θ1, θ2, and θ3, respectively) compared to the commercial OptiTrack system. In this comparison, an average goodness-of-FIT and normalized root mean square error of over 88.93% and 2.71% were obtained, respectively, for the joint relative angles of the hip and knee (θ1 and θ2) in all tests performed. However, the accuracy of the joint relative angle of the ankle (θ3, average FIT: 71.04% and nRMSE: 4.26%) was lower because of the low capture rate of the retroreflective markers in the smartphone system and the higher relative velocity in the lower extremities of the test subjects, which generated noise in the calculation of x-y trajectories. This decrease in accuracy has been reported in other studies. However, both motion capture systems experienced marker data loss at the hip, highlighting the need for improvement in the spatial distribution of the optical devices. The OptiTrack system demonstrated better optical redundancy but still required improvements. In contrast, the smartphone system, with its inherent limitations in terms of optical redundancy and spatial distribution, can be enhanced by incorporating multiple cameras for a three-dimensional view. Despite these limitations, the low-cost smartphone system showed optimal performance with minimal errors compared with the commercial system, making it a cost-effective option with potential for further development. The rapid advancement of smartphone technology and its accessibility make it an attractive choice for motion capture applications.

Funder

Departamento Administrativo de Ciencia, Tecnología e Innovación

University of the Valley

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3