Lower leg symmetry: a Q3D-CT analysis

Author:

Vuurberg GwendolynORCID,Dahmen Jari,Dobbe Iwan G. G.,Kleipool Roeland P.,Hayat Batur,Sierevelt Inger N.,Streekstra Geert,Kerkhoffs Gino M. M. J.,Stufkens Sjoerd A. S.

Abstract

Abstract Purpose In fracture and realignment surgery, the contralateral unaffected side is often used as a model or template for the injured bone even though clinically valuable quantitative data of bilateral symmetry are often unavailable. Therefore, the objective of the present study was to quantify and present the bilateral symmetry of the tibia and fibula. Methods Twenty bilateral lower-leg CT scans were acquired in healthy volunteers. The left and right tibia and fibula were segmented resulting in three-dimensional polygons for geometrical analyses (volume, surface and length). The distal and proximal segment of the right tibia of each individual was subsequently matched to the left tibia to quantify alignment differences (translation and rotation). Bone symmetry on group level was assessed using the Student’s t test and intra-individual differences were assessed using mixed-models analyses. Results Intra-individuals differences were found for tibia volume (5.2 ± 3.3 cm3), tibia surface (5.2 ± 3.3 cm2), translations in the lateral (X-axis; 9.3 ± 8.9 mm) and anterior direction (Y-axis; 7.1 ± 7.0 mm), for tibia length (translation along Z-axis: 3.1 ± 2.4 mm), varus/valgus (φz: 1.7o ± 1.4°), and endotorsion/exotorsion (φz: 4.0o ± 2.7°). Conclusion This study shows intra-individual tibia asymmetry in both geometric and alignment parameters of which the surgeon needs to be aware in pre-operative planning. The high correlation between tibia and fibula length allows the ipsilateral fibula to aid in estimating the original tibia length post-injury. Future studies need to establish whether the found asymmetry is clinically relevant when the contralateral side is used as reference in corrective surgery. Level of evidence III cohort study.

Funder

Marti Keuning Eckhart stichting

Musculoskeletal Imaging Quantification Center

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Pathology and Forensic Medicine,Surgery,Anatomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3