Comparison of safety and haemodynamic performance between the Avalus™ stented aortic valve bioprosthesis and Magna™ valve in Japanese patients

Author:

Tadokoro Naoki,Fukushima Satsuki,Shimahara Yusuke,Saito Tetsuya,Kawamoto Naonori,Kakuta Takashi,Minami Kimito,Fujita TomoyukiORCID

Abstract

Abstract Objectives A new stented bovine pericardial valve (Avalus™) has been proven safe and effective with good hemodynamic performance in Western populations. However, its use in Japanese patients is poorly understood. We retrospectively compared the feasibility, safety, and valve haemodynamics between the Avalus™ and Magna™ valves in patients who underwent surgical aortic valve replacement (SAVR). Methods This study included 87 patients receiving an Avalus™ valve and 387 receiving a Magna™ valve. We evaluated adverse events, outcomes, and valve haemodynamics within 1 year postoperatively. There were no significant differences in any surgical risk scores. Results No in-hospital mortality occurred in the Avalus™ group, but two mortality events occurred in the Magna™ group. No pacemaker implantation for complete atrioventricular block was required in the Avalus™ group. There was no significant difference in in-hospital or clinical outcomes between the two groups until 1 year postoperatively. Left ventricular mass index reduction appeared to predominate in the Avalus™ over Magna™ group. There was no significant difference in the mean pressure gradient or effective orifice area of each valve size at 1 week or 1 year between the two groups, apart from the mean pressure gradient of the 23-mm valve at 1 week. Three patients (3.4%) in the Avalus™ group and 39 (10.8%) in the Magna™ group (p = 0.12) had severe patient–prosthesis mismatch at 1 week postoperatively. Conclusions The new Avalus™ stented aortic valve bioprosthesis was associated with good in-hospital outcomes and good valve functionality post-SAVR in Japanese patients.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Reference15 articles.

1. Klautz RJM, Kappetein AP, Lange R, Dagenais F, Labrousse L, Bapat V, et al. Safety, effectiveness and haemodynamic performance of a new stented aortic valve bioprosthesis. Eur J Cardiothorac Surg. 2017;52:425–31.

2. Sabik JF 3rd, Rao V, Lange R, Kappetein AP, Dagenais F, Labrousse L, et al. One-year outcomes associated with a novel stented bovine pericardial aortic bioprosthesis. J Thorac Cardiovasc Surg. 2018;156(1368–77):e5.

3. Akins CW, Miller DC, Turina MI, Kouchoukos NT, Blackstone EH, Grunkemeier GL, et al. Guidelines for reporting mortality and morbidity after cardiac valve interventions. J Thorac Cardiovasc Surg. 2008;135:732–8.

4. Bonow RO, Brown AS, Gillam LD, Kapadia SR, Kavinsky CJ, Lindman BR, et al. ACC/AATS/AHA/ASE/EACTS/HVS/SCA/SCAI/SCCT/SCMR/STS 2017 Appropriate use criteria for the treatment of patients with severe aortic stenosis: a report of the American College of Cardiology Appropriate Use Criteria Task Force, American Association for Thoracic Surgery, American Heart Association, American Society of Echocardiography, European Association for Cardio-Thoracic Surgery, Heart Valve Society, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons. J Am Soc Echocardiogr. 2018;31:117–47.

5. Haude M. Management of valvular heart disease: ESC/EACTS guidelines 2017. Herz. 2017;42:715–20.

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3