Hemodynamic Comparison between the Avalus and the Perimount Magna Ease Aortic Bioprosthesis up to 5 Years

Author:

Burri Melchior12ORCID,Bozini Nikoleta12,Vitanova Keti12,Mayr Benedikt12,Lange Rüdiger123,Günzinger Ralf12

Affiliation:

1. Department of Cardiovascular Surgery, German Heart Centre Munich at the Technical University Munich, Munich, Germany

2. Department of Cardiovascular Surgery, Insure (Institute for Translational Cardiac Surgery), German Heart Center Munich at the Technical University of Munich, Munich, Germany

3. DZHK (German Center for Cardiovascular Research)-partner Site Munich Heart Alliance, Munich, Germany

Abstract

Abstract Background We aimed to compare hemodynamic performance of the Avalus (Medtronic) and the Perimount Magna Ease (PME, Edwards Lifesciences) bioprosthesis up to 5 years by serial echocardiographic examinations. Methods In patients undergoing aortic valve replacement, 58 received PME prostheses between October 2007 and October 2008, and another 60 received Avalus prostheses between October 2014 and November 2015. To ensure similar baseline characteristics, we performed a propensity score matching based on left ventricular ejection fraction, age, body surface area, and aortic annulus diameter measured by intraoperative transesophageal echocardiography. Thereafter, 48 patients remained in each group. Mean age at operation was 67 ± 6 years and mean EuroSCORE-II was 1.7 ± 1.1. Both values did not differ significantly between the two groups. Results At 1 year the mean pressure gradient (MPG) was 15.4 ± 4.3 mm Hg in the PME group and 14.7 ± 5.1 mm Hg in the Avalus group (p = 0.32). The effective orifice area (EOA) was 1.65 ± 0.45 cm2 in the PME group and 1.62 ± 0.45 cm2 in the Avalus group (p = 0.79). At 5 years the MPG was 16.6 ± 5.1 mm Hg in the PME group and 14.7 ± 7.1 mm Hg in the Avalus group (p = 0.20). The EOA was 1.60 ± 0.49 cm2 in the PME group and 1.51 ± 0.40 cm2 in the Avalus group (p = 0.38). Five-year survival was 88% in the PME group and 91% in the Avalus group (p = 0.5). In the PME group, there were no reoperations on the aortic valve, whereas in the Avalus group three patients required a reoperation due to endocarditis. Conclusion Both bioprostheses exhibit similar hemodynamic performance during a 5-year follow-up.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3