Abstract
AbstractThe design of medical devices is challenging, due to strict geometry specifications and criteria belonging to several disciplines. The aim of this paper is to provide a design methodology which seems to lack in the literature of design of biomedical devices. In particular, the case study proposed in this paper concerns with the design of Bone-Biopsy (BB) needle devices. Following the design process of Pahl and Beitz, a functional analysis is carried out, to point out the interfaces between parts of existing BB needles. A morphology matrix is used to generate alternatives for the cannula holder, the core part of the product. Generated alternatives have been ranked and scored by means of the Pugh’s Controlled Convergence method according to the decision makers' opinions. In this work, the design peculiarities related to the BB needles which have been pointed out could be extended for guiding the design of other biomedical devices.
Publisher
Springer International Publishing
Reference11 articles.
1. Keulers, A., Cunha-Cruz, V.C., Bruners, P., Penzkofer, T., Braunschweig, T., Schmitz-Rode, T., Mahnken, A.: Bone biopsy needles: mehanical properties, needle design and specimen quality [Knochen-biopsiesysteme: Mechanische eigenschaften, nadeldesign und probenqualität]. RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren 183(3), 274–281 (2011) 2. Misiewicz, J., Nguyen, B., Poudyal, A., Wachrathit, K., Chen, Y., Vossoughi, J.: A fiber optic enhanced bone biopsy needle. In: 2012 38th Annual Northeast Bioengineering Conference, NEBEC 2012, pp. 382–383. (2012) Art. no. 6207124 3. Giovannini, M., Ren, H., Cao, J., Ehmann, K.: Study on design and cutting parameters of rotating needles for core biopsy. J. Mech. Behav. Biomed. Mater. 86, 43–54 (2018) 4. Roberts, C.C., Morrison, W.B., Leslie, K.O., Carrino, J.A., Lozevski, J.L., Liu, P.T.: Assessment of bone biopsy needles for sample size, specimen quality and ease of use. Skeletal Radiol. 34(6), 329–335 (2005) 5. Uhl, M., Theves, C., Geiger, J., Kersten, A., Strohm, P.C.: The percutaneous bone biopsy: in vitro study for comparison of bone biopsy needles [Die perkutane Knochenbiopsie: Experimentelle Studie zum Vergleich von Knochenbiopsiesystemen]. Zeitschrift für Orthopädie und Unfallchirurgie 147(3), 327–333 (2009)
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|