Abstract
AbstractWe present a case study that provides a practical step-by-step example of how the internal Threshold of Toxicological Concern (iTTC) can be used as a tool to refine a TTC-based assessment for dermal exposures to consumer products. The case study uses a theoretical scenario where there are no systemic toxicity data for the case study chemicals (avobenzone, oxybenzone, octocrylene, homosalate, octisalate, octinoxate, and ecamsule). Human dermal pharmacokinetic data following single and repeat dermal exposure to products containing the case study chemicals were obtained from data published by the US FDA. The clinical studies utilized an application procedure that followed maximal use conditions (product applied as 2 mg/cm2 to 75% of the body surface area, 4 times a day). The case study chemicals were first reviewed to determine if they were in the applicability domain of the iTTC, and then, the human plasma concentrations were compared to an iTTC limit of 1 µM. When assessed under maximum usage, the external exposure of all chemicals exceeded the external dose TTC limits. By contrast, the internal exposure to all chemicals, except oxybenzone, was an order of magnitude lower than the 1 µM interim iTTC threshold. This work highlights the importance of understanding internal exposure relative to external dose and how the iTTC can be a valuable tool for assessing low-level internal exposures; additionally, the work demonstrates how to use an iTTC, and highlights considerations and refinement opportunities for the approach.