Do Sensor Glucose Levels Accurately Predict Plasma Glucose Concentrations During Hypoglycemia and Hyperinsulinemia?

Author:

Monsod Teresa P.1,Flanagan Daniel E.2,Rife Fran3,Saenz Rebecca1,Caprio Sonia1,Sherwin Robert S.2,Tamborlane William V.14

Affiliation:

1. Department of Pediatrics, Yale University School of Medicine, New Haven, Connecticut

2. Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut

3. General Clinical Research Centers, Yale University School of Medicine, New Haven, Connecticut

4. Pediatric Pharmacology Research Unit, Yale University School of Medicine, New Haven, Connecticut

Abstract

OBJECTIVE—The MiniMed Continuous Glucose Monitoring System (CGMS) measures subcutaneous interstitial glucose levels that are calibrated against three or more fingerstick glucose levels daily. The objective of the present study was to examine whether the relationship between plasma and interstitial fluid glucose is altered by changes in plasma glucose and insulin levels and how such alterations might influence CGMS performance. RESEARCH DESIGN AND METHODS—Arterialized plasma glucose, sensor glucose, and interstitial fluid glucose were measured by microdialysis in 11 healthy subjects during a 1.0 mU · kg−1 · min−1 stepped euglycemic-hypoglycemic-hyperglycemic (plasma glucose ∼5, 3.1, and 8.6 mmol/l, respectively) insulin clamp that raised plasma insulin to ∼360–390 pmol/l. RESULTS—When the CGMS was calibrated versus plasma glucose levels before insulin infusion, basal sensor and plasma glucose were similar (5.0 ± 0.3 vs. 5.2 ± 0.3 mmol/l, respectively); dialysate glucose was 3.3 ± 0.9 mmol/l. During the hyperinsulinemic-euglycemia study (plasma glucose 4.9 ± 0.3 mmol/l), dialysate glucose fell by 30–35%, accompanied by a significant reduction in sensor glucose (to 3.7 ± 0.6 mmol/l; P < 0.001 vs. plasma). Subsequently, sensor levels remained lower than plasma values during mild hypoglycemia (2.5 ± 0.6 vs. 3.1 ± 0.3 mmol/l; P < 0.01) and during recovery from hypoglycemia (7.3 ± 1.2 vs. 8.6 ± 0.6; P < 0.01). However, when the CGMS was calibrated against plasma glucose levels before and during each step of the clamp, sensor glucose levels increased throughout the study and did not differ from plasma glucose values during hypoglycemia. CONCLUSIONS—Although hyperinsulinemia may contribute to modest discrepancies between plasma and sensor glucose levels, the CGMS is able to accurately track acute changes in plasma glucose when calibrated across a range of plasma glucose and insulin levels.

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

Cited by 156 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3