Stability of Insulin Lispro in Insulin Infusion Systems

Author:

Lougheed William D1,Zinman Bernard2,Strack Thomas R3,Janis Linda J4,Weymouth Alexandra B4,Bernstein Elyse A4,Korbas Annette M4,Frank Bruce H4

Affiliation:

1. LTBO (Loyal True Blue & Orange) Research Institute Richmond Hill, Ontario, Canada

2. Samuel Lunenfeld Research Institute, University of Toronto Toronto, Ontario, Canada

3. Eli Lilly Canadas Toronto, Ontario, Canada

4. Lilly Research Laboratories Indianapolis, Indiana

Abstract

OBJECTIVE To test stability of insulin lispro in two insulin infusion systems over 48 h. RESEARCH DESIGN AND METHODS We used reverse-phase and size-exclusion high-performance liquid chromatography (HPLC) to determine the purity, potency, and degree of polymerization of U100 insulin lispro (Humalog) after 24- and 48-h pump cycles conducted at 37°C in five Disetronic H-TRON V100 and five MiniMed 504 pumps. Pumps were set to deliver a basal rate of 0.5 U/h and 6-U boluses at t = 0, 4, 8, 24, 24.5, 28.5, 32.5, and 48 h during each cycle. The effluent was collected into 1-ml vials, pooled at 24 or 48 h, and stored at 4°C until assay. After each 48-h run period of insulin delivery, assays for potency, polymer, and purity were performed on the pooled samples from each individual cycle. m-cresol content and the pooled reservoir content were assayed in the 48-h pooled samples. RESULTS Insulin lispro retained full HPLC potency (Δ ≤ 4%) at 48 h, with no degradation of insulin lispro to des-amidoinsulin forms (24 or 48 h). No increase in pumped insulin polymer concentration was observed following 24 h of pump flow. Nonsignificant increases of ≤0.09% (Disetronic) and ≤0.15% (MiniMed) from initial concentrations of 0.18% (polymer divided by total insulin) were detected in three of five pump cycles at 48 h when compared with 37°C paired controls. Nonsignificant decreases (<5 and 10%, Disetronic and MiniMed, respectively) of m-cresol content occurred in both systems following 48 h storage in each device, but sterility was not compromised by this decrease (initial m-cresol concentration, 3.15 mg/ml). Pump performance was without mechanical or electrical fault throughout the study Basal and bolus insulin delivery was evaluated three times daily and remained as expected. Occlusion of catheters by insulin precipitation did not occur, and no change in pH was observed following delivery. CONCLUSIONS We conclude that insulin lispro is suitable for prolonged infusion in these two medical devices when syringes and catheters are replaced at 48-h intervals.

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

Cited by 44 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3