Affiliation:
1. Kanuni Anadolu İmam Hatip Lisesi
Abstract
The proposed study describes a novel and disposable voltammetric sensor that designed for the sensitive determination of celestine blue (CelsB) using a pencil graphite electrode (PGE). The electrochemical characterization study of the designed sensor was performed by recording the cyclic voltammograms (CVs) and electrochemical impedance (EI) curves in 5.0 mM of Fe(CN)63-/4- including 0.10 M of KCl, and compared with the other carbon-based electrodes such as carbon paste (CPE) and glassy carbon (GCE) electrodes. The electrochemical behaviour of CelsB was examined at different carbon-based electrodes including PGE, CPE, and GCE by the cyclic voltammetric (CV) method. The recorded CVs showed that the remarkable response obtained at PGE toward oxidation of CelsB. Moreover, the PGE shows a wide linear range (4.0 − 150 μM) and detects the CelsB with a notable limit of detection (1.21 μM). In addition, the results from the interference studies proved that the PGE enables selective voltammetric determination of CelsB in presence of various species. A feasibility study for CelsB sensor was also tested on tap water and cherry apple juice samples and the recovery values obtained between 96.2 − 103 % with high precision and accuracy indicated that the PGE shows an acceptable and good applicability to real samples.
Publisher
Canakkale Onsekiz Mart University
Reference28 articles.
1. V. Aruna Janani, D. Gokul, N. Dhivya, A. Nesarani, K. Mukilan, A. Suresh Kumar, M. Vignesh Kumar, Optimization studies on methyl orange (MO) dye adsorption using activated carbon nanoadsorbent of ocimum basilicum linn leaves, Journal of Nanomaterials 2023 (2023) Article ID 7969512 14 pages.
2. M. Roushani, Z. Saedi, Z. Mirzaei Karazan, A. Azadbakhat, Electrochemical detection of celestine blue based on screen printed carbon electrode modified with molecular imprinted polymer and NiO nanoparticles, Analytical and Bioanalytical Chemistry Research 8 (4) (2021) 493–504.
3. K. G. Akpomie, J. Conradie, Biosorption and regeneration potentials of magnetite nanoparticle loaded solanum tuberosum peel for celestine blue dye, International Journal of Phytoremediation 23 (4) (2021) 347–361.
4. P. S. Ganesh, G. Shimoga, S. H. Lee, S. Y. Kim, E. E. Ebenso, Interference free simultaneous detection of dihydroxy benzene isomers at cost‐effective and reliable celestine blue modified glassy carbon electrode, ChemistrySelect 6 (9) (2021) 2379–2386.
5. Y. Chen, Y. Zhong, J. X. Ye, Y. Lei, A. L. Liu, Facile label-free electrochemical dna biosensor for detection of osteosarcoma-related survivin gene, Biosensors 12 (9) (2022) 747 11 pages.