Benchtop lab equipment, such as the HP4194A Precision Impedance Analyzer, offer accuracy and functionality but are often expensive and bulky. Although integrated circuits offer less functionality than benchtop equivalents, they can be a cheaper alternative for smaller applications. In this study, the AD5933 Impedance Converter was investigated as a low-cost option for impedance analysis of the bicep brachii. The AD5933 evaluation board was properly calibrated to measure human muscle by using an equivalent parallel circuit consisting of a 5 nF capacitor and a 1 kOhm resistor. Next, the impedance of the bicep was measured using the AD5933 as the experimental device and the HP4194A as the control device. A 2 volt peak-to- peak signal was generated for a 10 kHz to 100 kHz frequency range and the resulting impedance of the bicep was measured. The AD5933 recorded impedance curves qualitatively and quantitatively similar to those recorded by the HP4194A. Thus, the AD5933 was considered to be a low- cost alternative for impedance analysis in small-scale medical applications.

Publisher

Southern Methodist University

Reference8 articles.

1. AnalogDevices.2005.1MSPS,12-Bit Impedance Converter, Network Analyzer. AD5933 technical datasheet. Analog Devices, Norwood, MA.

2. Analog Devices. AD5933 Evaluation Board Software Rev. B. Technical Software Interface. Analog Devices, Norwood, MA.

3. Analog Devices. 2005. Evaluating the AD5933 1 MSPS, 12-Bit Impedance Converter Network Analyzer EVAL- AD5933EBZ technical datasheet. Analog Devices, Norwood, MA.

4. Paul Horowitz and Winfield Hill. 2016. The Art of Electronics, New York, NY: Cambridge University Press.

5. Keysight Technologies. Agilent 4194A Precision Impedance Analyzer 4194A technical datasheet. Keysight Technologies, Santa Rosa, CA.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A Low Cost Bioimpedance Measurement System Based on AD5933 Chip;2023 International Conference on Decision Aid Sciences and Applications (DASA);2023-09-16

2. Bone Healing Monitoring in Bone Lengthening Using Bioimpedance;Journal of Healthcare Engineering;2022-04-07

3. β-Dispersion of blood during sedimentation;Scientific Reports;2021-01-29

4. Simple Wireless Impedance Pneumography System for Unobtrusive Sensing of Respiration;Sensors;2020-09-14

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3