The Value and Application of Personalized Needle Modification in Percutaneous Infrazygomatic Radiofrequency in Isolated Maxillary Nerve Pain through the Foramen Rotundum

Author:

Huang Bing1

Affiliation:

1. 2 First Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang Province, China

Abstract

Background: Percutaneous infrazygomatic radiofrequency (PIR) is a common approach used to block isolated maxillary nerve (V2) pain through the foramen rotundum (FR) in patients with trigeminal neuralgia (TN). Nevertheless, when using this method, there is a risk of accidental penetration of the superior orbital fissure (SOF) and the optic canal (OC) that may result in the injury of the vessels and nerves in that area, and in some severe cases may lead to blindness. According to the blocking of the external orifice of the FR and whether a curved needle was used, combined angle deviation from the path of percutaneous infrazygomatic approach, the FR to the SOF or the OC in the treatment of V2 pain, in which no research has reported the angle, we analyzed the value and application of personalized needle modification in PIR in isolated maxillary nerve pain through the FR. Objectives: The following study examined the relationship between the FR and the SOF, and analyzed the clinical significance of personalized needle modification in computed tomography (CT)-guided PIR ablation of the maxillary nerve through the FR in patients with TN. Study Design: Randomized, review, clinical research study. Setting: Department of Anesthesiology and Pain Medical Center, Jiaxing, China. Methods: Three-dimensional reconstruction was performed in 88 patients and 136 patients with PIR ablation in isolated maxillary nerve pain through the FR. According to the blocking of the external orifice of the FR and whether a curved needle was used, patients were divided into 4 groups: curvedneedle blocking group (CB), straight-needle blocking group (SB), straight needle no-blocking group (SN), and curved-needle no-blocking group (CN). Results: The results obtained revealed minimum H (shortest diameter of the FR) = 1.0 mm and minimum L (length of the FR tubes) = 3.7 mm. The distance between the external orifice of the FR and the SOF (FS) was 5.16 ± 1.33 mm. The angle A (between the radiofrequency needle and the sagittal plane) was 39 ± 3.95°; the angle between the canthomeatal line and the CT scan line (ACT) was 58.99 ± 6.23°; the puncture depth (LS) was 63.99 ± 4.24 mm; the deviation angle of the misplacement into the SOF (SAF) was 2.96 ± 0.71°; the deviation angle of the misplacement into the OC (OAF) was 4.95 ± 0.73°. In addition, the postoperative Numeric Rating Scale scores in the CB group were significantly lower compared with the SB group, whereas the probability of entering the SOF in the CB group was significantly lower compared with the SB group. The total number of punctures in the SN group was less than that in the CN group. Limitations: Additional clinical data should be collected to preserve the results in future work. Conclusions: The distance between the FR and the SOF or the OC was only few millimeters, and slight angle error could lead to the SOF and the OC. For patients with blockage in the path, the treatment of radiofrequency with personalized needle modification could improve the curative effect and reduce the risk of accidental SOF penetration. Key words: Trigeminal neuralgia, foramen rotundum, superior orbital fissure, radiofrequency, personalized needle modification

Publisher

American Society of Interventional Pain Physicians

Subject

Anesthesiology and Pain Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3